background image

2

© 2015 Monte Carlo Fan Company

4/25/2015

Cautions and Warnings

Installation work and electrical wiring must be done by qualified person(s) in accordance with applicable codes and standards (ANSI/NFPA 

70-1999), including fire-rated construction.
Use this unit only in the manner intended by the manufacturer.  If you have  any questions contact the manufacturer.
After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor 

on one side of the outlet box and ungrounded conductor on the other side of the outlet box. The splices, after being made, should be 

turned upward and pushed carefully up into the outlet box.

WARNING:

 Before you begin installing the fan, servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting 

means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a 

prominent warning device, such as a tag, to the service panel.
Be cautious! Read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet 

from the floor to the trailing edge of the blade.

WARNING:

 To Reduce The Risk Of Fire, Electric Shock, or Personal Injury, Mount To Outlet Box Marked “Acceptable for Fan Support of 

15.9 kg (35 lbs) or less” And Use Mounting Screws Provided With The Outlet Box.

CAUTION

: For Compliance with Local Codes and Regulations, If Installing The Secondary Support Safety Cable in the U.S., Do Not Remove 

Knockouts In The Outlet Box. Mount the secondary support safety cable through the reserved nail/screw hole on the outlet box to the 

building structure (or the ceiling joist).

WARNING:

 To reduce the risk of personal injury, do not bend blade holders during installation to motor, balancing or during cleaning.  Do 

not insert foreign object between rotating blades.
Attach the mounting bracket using only the hardware supplied with the outlet box.

WARNING:

 To reduce the risk of fire or electric shock, this fan must be installed with an isolating wall control/switch.

WARNING:

 To reduce the risk of fire or electric shock, do not use this fan with any unverified solid state fan speed control device, or 

variable speed control.
If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.
Never place a switch where it can be reached from a tub or shower.
The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating 

equipment manufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA), and the 

American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

CAUTION:

 To Reduce the Risk of Electric Shock, Disconnect the electrical supply circuit to the fan before installing the light kit. 

All set screws must be checked and tightened where necessary before installation. 

Tools Required for Assembly (not included): Electrical Tape, Phillips Screwdriver, Pliers, Safety Glasses, Stepladder and Wire Strippers

WARNING:

 TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING

 READ AND SAVE THESE INSTRUCTIONS

Customer Service

800-969-3347

Customer Service Center

7400 Linder Ave.

Skokie, IL 60077

www.montecarlofans.com

Содержание 5CQM52XX-L Series

Страница 1: ...OF PURCHASE MODEL NUMBER RETAILER NAME RETAILER ADDRESS Attach sales receipt to this card and retain as your proof of purchase To register your fixture please visit our website www montecarlofans com...

Страница 2: ...he Secondary Support Safety Cable in the U S Do Not Remove Knockouts In The Outlet Box Mount the secondary support safety cable through the reserved nail screw hole on the outlet box to the building s...

Страница 3: ...en the service disconnecting means cannot be locked securely fasten a warning device such as a tag to the service panel Fig 1 Before installing this fan make sure the outlet box is properly installed...

Страница 4: ...her side and insert keeper pin on cross pin Pull the downrod up tight against the cross pin and then evenly tighten the downrod set screws on motor housing yoke Fig 3 Warning Cross pin and keeper pin...

Страница 5: ...canopy over the mounting bracket hook Use one of non slotted holes on the rim of the canopy Fig 5 2 Safety Cable Installation For Canadian installation and for USA fan and light kit combinations over...

Страница 6: ...Installation Partially loosen 2 of the set screws on mounting bracket corresponding to the slotted holes on the canopy upper ring Remove the other 2 set screws Save screws Raise canopy to mounting br...

Страница 7: ...y to motor using the preinstalled screws Tighten screws securely Repeat this process for remaining blade assemblies Fig 9 Note Tighten blade bracket screws twice a year Switch housing installation and...

Страница 8: ...ke sure that canopy mounting bracket or mounting plate are tightened securely to ceiling 4 Check that all blade holders are tightened securely to motor 5 Most fan wobble problems are caused when blade...

Страница 9: ...Apr 2015...

Отзывы: