background image

Page 2 – Builder Supreme-English CUL

© Copyright 1996, Monte Carlo Fan Co.REV.1,12/14/01

1

2

3

TOOLS REQUIRED

Phillips Screwdriver      Wire Cutters      Pliers      Step Ladder

Unpack and inspect fan carefully to be
certain all contents are included. (See
exploded view parts list.)

Turn off power at breaker box to avoid
possible electrical shock.

Use outlet box suitable for fan support.
Secure outlet box directly to the building
structure using ceiling joist screws.
Outlet box must support 35 lbs.

4

Install mounting bracket to outlet box
in ceiling using the screws  and
washers provided with the outlet box.

5

Feed motor lead wires through downrod/
canopy assembly and insert downrod into
motor yoke. Next, insert clevis pin through
yoke and downrod and secure with cotter
pin. (see inset) Tighten both yoke set
screws to further secure downrod.

6

Clevis

Pin

Set

Screws

Cotter

Pin

Ridge

Ball
Notch

Safety Tips

WARNING: 

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

READ  AND SAVE THESE INSTRUCTIONS

I

NSTALLATION

1.

2.
3.

4.

5.
6.
7.

8.

9.
10.
11.
12.
13.
14.

15.

Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards(ANSI/NFPA 70-
1996), including fire-rated construction.
Use this unit only in the manner intended by the manufacurer.  If you have  any questions contact the manufacturer.
After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on
one side of the outlet box and ungrounded conductor on the other side of the outlet box.
Before you begin installing the fan, Switch power off at Service panel and lock service disconnecting means to prevent power from being
switched on accidentally.  When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such  as a tag,
to the service panel.
Be cautious! read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet from the
floor to the trailing edge of the blade.
To reduce the risk of fire, electric shock, or personal injury, mount to outlet box or supporting system acceptable for fan support.
Use mounting screws provided with the outlet box.             (Mounting must support at least 35 lbs.)
Do not bend blade holders during installation to motor, balancing or during cleaning.  Do not insert foreign object between rotating blades.
Attach the mounting bracket using only the hardware supplied with the outlet box.
To reduce the risk of fire or electric shock, do not use this fan with any solid state fan speed control device, or variable speed control.
If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.
NEVER place a switch where it can be reached from a tub or shower.
The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating
equipment manufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NEPA), and the
American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.
Before servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting means to prevent power from being switched
on accidentally.  When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such  as a tag, to the
service panel.

Carefully lift fan assembly onto
mounting bracket. Rotate fan so that
the notch on the ball engages the ridge
in the mounting bracket. This will allow
hands-free wiring.

Отзывы: