background image

1.Check main and branch circuit fuses or circuit breakers.

2.Check line wire connections to fan and switch wire connections in switch housing.

CAUTION:  Make sure main power is turned off.

3.Make sure forward/reverse switch is firmly in up or down position.  Fan will not operate when

switch is in the middle.

4.Make sure that shipping stabilizer tabs have been removed from motor.

1.Check to make sure all screws in motor housing are snug (not over tightened).

2.Check to make sure the screws which attach the fan blade holder to the motor are tight.

3.Check to make sure wire nut connectors in switch housing are not rattling against each other or

against the interior wall of the switch housing.

CAUTION:  Make sure main power is turned off before entering switch housing.

4.If using an optional Ceiling Fan Light Kit, check to be sure the screws securing the glassware are

finger tight.  Check to be sure light bulb is tight in socket and not touching glass shade(s). If vibra-

tion persists from glass, remove glass and install a 1/4" wide rubber band on glass neck to act as

an insulator. Replace glass and tighten screws against rubber band. 

5.Some fan motors are sensitive to signals from Solid State variable speed controls.  

DO NOT USE a Solid State variable speed control.

6.Allow "break-in" period of 24 hours.  Most noises associated with a new fan will disappear after

this period.

1.Make sure that the ridge of the canopy engages the notch in the downrod ball.  (See illustration in

Step #6 of Downrod Mount installation).

2.Check that all blades are screwed firmly into blade holders.

3.Check that all blade holders are tightened securely to motor.

4.Make sure that canopy and mounting bracket are tightened securely to ceiling junction box and

junction box is mounted firmly to ceiling joist.

5.Most fan wobble problems are caused when blade levels are unequal. Check this level by selecting

a point on the ceiling above the tip of one of the blades. Measure this distance from blade tip to

ceilng. Keeping measure within 1/8", rotate the fan until the next blade is positioned for measure-

ment. Repeat for each blade. If all blade levels are not equal, you can adjust blade levels by the fol-

lowing procedure. To adjust a blade tip down, insert a washer (not supplied) between the blade and

blade holder at the screw closest to the motor. To adjust a blade tip up, insert washer (not supplied)

between the blade and blade holder at the two screws farthest from the motor.  Reverse the posi-

tion of the washer if blades mount from top of blade.

6.If blade wobble is still noticeable, interchanging two adjacent (side by side) blades can redistrib-

ute the weight and possibly result in smoother operation.

1.Check blue wire from fan to make sure it is connected to hot wire from house.

2.Check for loose or disconnected wires in fan switch housing.

3.Check for loose or disconnected wires in light kit.

4.Check for faulty light bulbs.

CAUTION:  Make sure main power is turned off before entering switch housing.

2. If fan sounds noisy:

1. If fan does not start:

3. If fan wobbles:

4. If light does not work:

T

ROUBLE

S

HOOTING

If you have difficulty operating your new ceiling fan, it may be the result of incorrect assembly, installation, or wiring. In

some cases, these installation errors may be mistaken for defects. If you experience any faults, please check this Trouble

Shooting Chart. If a problem cannot be remedied, or you are experiencing difficulty in installation, please call our

Customer Service Center at the 

number printed on your parts list insert sheet. 

Warning: Before servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting

means to prevent power from being switched on accidentally.  When the service disconnecting means cannot

be locked, securely fasten a 

prominent warning device, such  as a tag, to the service panel.

Customer Service Center:

740 S.W. Loop 820, Suite 110

Fort Worth, Texas 76115

1-800-519-4092

Trouble

Suggested Remedy

Содержание 4CO28 Series

Страница 1: ...QUALITY CEILING FANS Ceiling Fan Installation Instructions For 4CO28 Series Fans READ AND SAVE THESE INSTRUCTIONS Total fan weight OWNER S MANUAL ...

Страница 2: ...of fuel burning equipment may be affected by this unit s operation Follow the heat ing equipment manufacturer s guideline safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities Before servicing or cleaning unit Switch power off at Service panel ...

Страница 3: ...he wires should be spread apart with the grounded con ductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box C Ca an na ad di ia an n m mo ou un nt ti in ng g o on nl ly y Safety Cable Lag Screw 11 Make sure the studs protruding from the bottom of the Mounting bracket are installed with threads all the way through the...

Страница 4: ... Repeat this process 3 more times until all blades are assembled Install blades to motor using the 8 motor screws provided Tighten screws securely 20 21 Lift fan to mounting bracket aligning the L shape holes with the scresws on the mount ing bracket Turn the fan clockwise to lock in position Re install the screws removed in the previous step and tighten securely 19 Install switch cap to fan using...

Страница 5: ...y selecting a point on the ceiling above the tip of one of the blades Measure this distance from blade tip to ceilng Keeping measure within 1 8 rotate the fan until the next blade is positioned for measure ment Repeat for each blade If all blade levels are not equal you can adjust blade levels by the fol lowing procedure To adjust a blade tip down insert a washer not supplied between the blade and...

Отзывы: