background image

Installation work and electrical wiring must be done by qualified person(s) in accordance with  applicable codes ANSI/NFPA 70-1999),

including fire-rated construction.

Use this unit only in the manner intended by the manufacturer.  If you have  any questions contact the manufacturer.

After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding con-

ductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box.

Before you begin installing the fan, Switch power off at Service panel and lock service disconnecting means to prevent power from

being switched on accidentally.  When the service disconnecting means cannot be locked, securely fasten a prominent warning device,

such  as a tag, to the service panel.

Be cautious! read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.

When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7

feet from the floor to the trailing edge of the blade.

To reduce the risk of fire, electric shock, or personal injury, mount to outlet box or supporting system acceptable for fan support. 

(Mounting must support at least 35 lbs.)

Do not bend blade holders during installation to motor, balancing or during cleaning.  Do not insert foreign object between rotating

blades.

Attach the mounting bracket using only the hardware supplied with the outlet box.

To reduce the risk of fire or electric shock, do not use this fan with any solid state fan speed control device, or variable speed control.

If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.

NEVER place a switch where it can be reached from a tub or shower.

The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heat-

ing equipment manufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA),

and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

Before servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting means to prevent power from being

switched on accidentally.  When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such

as a tag, to the service panel.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS,

OBSERVE THE FOLLOWING: READ AND SAVE THESE INSTRUCTIONS

S

AFETY

T

IPS

TOOLS REQUIRED

Phillips Screwdriver      Wire Cutters       Pliers      Step Ladder

Before you begin installing the fan, Switch

power off at Service panel and lock service dis-

connecting means to prevent power from being

switched on accidentally.  When the service dis-

connecting means cannot be locked, securely

fasten a prominent warning device, such as a

tag, to the service panel.

Before installing this fan make sure the outlet box is

properly installed to the house structure.  To reduce

the risk of fire, electric shock, or personal injury,

mount to outlet box or supporting system acceptable

for fan support. (Mounting must support at least 35

lbs.)

Insert downrod into yoke on top of the Fan

Body.  Align the hole in the Downrod with the

hole in the Yoke. Insert the Pin through the

Yoke and Downrod until the point appears on

the other side.  Install the Keeper Pin

Tighten the 2 Set screws on the Yoke

once the downrod is in place.

2

1

5

6

Yoke

Cross Pin

Keeper 

Pin

Installation

Use metal outlet box suitable for fan support

(must support 35 lbs). Before attaching fan to

outlet box, ensure the outlet box is securely

fastened by at least two points to a structural

ceiling member ( a loose box will cause the fan

to wobble). 

Use only the screws provided

with the outlet box.  

3

Tread leadwires and safety cable first

through the canopy disk, canopy and last

the downrod.

4

Canopy disk

Downrod

Canopy

Содержание 4CO28 Series

Страница 1: ...QUALITY CEILING FANS Ceiling Fan Installation Instructions For 4CO28 Series Fans READ AND SAVE THESE INSTRUCTIONS Total fan weight OWNER S MANUAL ...

Страница 2: ...of fuel burning equipment may be affected by this unit s operation Follow the heat ing equipment manufacturer s guideline safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities Before servicing or cleaning unit Switch power off at Service panel ...

Страница 3: ...he wires should be spread apart with the grounded con ductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box C Ca an na ad di ia an n m mo ou un nt ti in ng g o on nl ly y Safety Cable Lag Screw 11 Make sure the studs protruding from the bottom of the Mounting bracket are installed with threads all the way through the...

Страница 4: ... Repeat this process 3 more times until all blades are assembled Install blades to motor using the 8 motor screws provided Tighten screws securely 20 21 Lift fan to mounting bracket aligning the L shape holes with the scresws on the mount ing bracket Turn the fan clockwise to lock in position Re install the screws removed in the previous step and tighten securely 19 Install switch cap to fan using...

Страница 5: ...y selecting a point on the ceiling above the tip of one of the blades Measure this distance from blade tip to ceilng Keeping measure within 1 8 rotate the fan until the next blade is positioned for measure ment Repeat for each blade If all blade levels are not equal you can adjust blade levels by the fol lowing procedure To adjust a blade tip down insert a washer not supplied between the blade and...

Отзывы: