OFF

Before you begin installing the fan, Switch 

power off at Service panel and lock 

service disconnecting means to prevent 

power from being switched on 

accidentally.  When the service 

disconnecting means cannot be locked, 

securely fasten a  warning device, such  

as a tag, to the service panel.

Before installing this fan make sure the 

outlet box is properly installed to the 

house structure. To reduce the risk of 

fire, electric shock, or personal injury, 

mount to outlet box or supporting system 

acceptable for fan support. 

(Mounting must support at least 35 lbs.)

Use metal outlet box suitable for fan 

support and use only the screws provided 

with the outlet box  (must support 35 

lbs). Before attaching fan to outlet box, 

ensure the outlet box is securely fastened 

by at least two points to a structural 

ceiling member ( a loose box will cause 

the fan to wobble). Remove the two outlet 

box screws provided with the box, 

aligning the holes of the mounting 

bracket with the holes of the outlet box. 

Re-install the 2 outlet box screws 

securely.

Remove preassembled cross pin and 

keeper pin from motor housing yoke at 

top of motor assembly and partially 

loosen downrod set screws.

Place downrod over canopy, canopy 

bottom cap and yoke cover. Thread lead 

wires and safety cable from motor 

assembly through downrod.

Slip downrod into motor housing yoke, 

align holes and re-install cross pin and 

keeper pin. Re-tighten downrod set 

screws on motor housing yoke.

Place yoke cover to motor assembly by 

inserting the alignment post on yoke 

cover into the hole on top housing.  

Yoke cover

Canopy bottom

cap

Canopy

Downrod

Alignment post

Hole

Mounting bracket

Содержание 3VER56XXD Series

Страница 1: ...kit DATE OF PURCHASE MODEL NUMBER RETAILER NAME RETAILER ADDRESS Attach sales receipt to this card and retain as your proof of purchase To register your fixture please visit our website www montecarlofans com 3VER56XXD Series Fan UL Model NO AC 552 11 6 kgs 25 52 lbs ...

Страница 2: ...al injury do not bend blade holders during installation to motor balancing or during cleaning Do not insert foreign object between rotating blades Attach the mounting bracket using only the hardware supplied with the outlet box WARNING To reduce the risk of fire or electric shock this fan must be installed with an isolating wall control switch WARNING To reduce the risk of fire or electric shock t...

Страница 3: ...e attaching fan to outlet box ensure the outlet box is securely fastened by at least two points to a structural ceiling member a loose box will cause the fan to wobble Remove the two outlet box screws provided with the box aligning the holes of the mounting bracket with the holes of the outlet box Re install the 2 outlet box screws securely Remove preassembled cross pin and keeper pin from motor h...

Страница 4: ...white from remote marked N Blue from fan to blue from remote marked light Black from fan to Black from remote marked L White from house to white from remote marked AC N Black from house to Black from remote marked AC L Connect all green grounded wires to Grounded wire from House Make sure that no filaments are outside of the wirenuts Insert the remote receiver into mounting bracket Loosen one and ...

Страница 5: ...te wire from fan to white wire from light fixture and then connect black wire from fan to black wire from light fixture Attach light fixture onto light pan aligning the keyhole slots on the light fixture with the screws on light pan and twist clockwise till tight Reinstall the screw removed in step 16 Tighten all screws securely Install 13W CFL medium base bulb Bulb included WARNING USE MAXIMU 13 ...

Страница 6: ...A23 GP 23A all 12V Attach cover of remote by placing over buttons and snap the battery cover in place Place battery cover over battery compartment and buttons Place remote over 2 pins on front cover Attach cover of remote by placing over 4 pins and snapping into place Install wall control unit to outlet box using machine screws provised Attach front cover to wall control unit with screws provided ...

Страница 7: ...low a few seconds for fan to slow down and change rotation direction Clicking noise may be heard after depressing button WARNING This fixture is not dimmable Use only with on off switch Do not use in conjunction fan light remote controls or light dimmers Remote Control Transmitter Features MEDIUM SPEED HIGH SPEED LIGHT ON OFF SETTING Press to turn light on off LED LIGHT LOW SPEED FAN OFF SETTING T...

Страница 8: ...SHDU DIWHU WKLV SHULRG I WKLV LV D GRZQURG PRXQW IDQ PDNH VXUH WKDW WKH ULGJH RI WKH FDQRS HQJDJHV WKH QRWFK LQ WKH GRZQURG EDOO 0DNH VXUH WKDW FDQRS PRXQWLQJ EUDFNHW RU PRXQWLQJ SODWH DUH WLJKWHQHG VHFXUHO WR FHLOLQJ MXQFWLRQ ER DQG MXQFWLRQ ER LV PRXQWHG UPO WR FHLOLQJ MRLVW KHFN WKDW DOO EODGHV DUH VFUHZHG UPO LQWR EODGH KROGHUV KHFN WKDW DOO EODGH KROGHUV DUH WLJKWHQHG VHFXUHO WR PRWRU 0RVW ID...

Страница 9: ...Mar 2012 ...

Отзывы: