Remove the set screws from yoke. Keep 

the screws. 

Place the top housing over lead wires, 

safety cable and the yoke. Replace the 

set screws and tighten all the screws. 

Partially loosen downrod set screws from 

yoke at top of motor assembly.

Remove preassembled cross pin and 

keeper pin from downrod. Keep parts. 

Place downrod over canopy, canopy 

bottom cap and yoke cover. Thread lead 

wires and safety cable from motor.

Slip downrod into motor housing yoke, 

aligning holes and install cross pin and 

keeper pin. 

Insert cross pin through yoke and downrod 

until point appears on the other side, and 

insert keeper pin on cross pin. 

Pull the downrod up tight against the 

cross pin, and then evenly tighten the 

downrod set screws on motor housing 

yoke. 

Place yoke cover on top housing of fan.

Warning

: Cross pin and keeper pin must 

be installed securely, failure to install them 

will result in serious injury.

Install ball end of downrod into mounting 

bracket opening. Align (engage) slot on 

ball with tab on mounting bracket.

Warning:

 Failure to align slot on ball with 

tab may result in serious injury.

Important

: If using the angle mount, 

make sure open end of mounting bracket 

is installed facing the higher point of the 

ceiling and make sure the ceiling angle is 

not steeper than 20º. Longer downrod 

may be necessary allowing the fan blades 

to rotate without obstructions.    

Safety cable must be installed into the 

house structure using 3” lag screws, 

washers, and lock washers provided, 

required for outdoor applications and in 

Canada (All fans installed in Canada), and 

for USA fan and light kit combinations 

over 35lbs. 

Make sure that when the safety cable is 

fully extended the lead wires are longer 

than the cable and no stress is placed on 

the lead wires.

Note

: If Installing The Secondary Support 

Safety Cable in the U.S., Do Not Remove 
Knockouts In The Outlet Box.

  

SAFETY CABLE INSTALLATION

Lag screw

Safety cable

Washer

Lock washer

Keeper pin

Cross pin

Downrod

Cross pin

Keeper pin

Tab

Slot

Top

housing

Yoke

Canopy

Downrod

Canopy bottom cap

Yoke cover

Содержание 3JVR58 D Series

Страница 1: ... NAME RETAILER ADDRESS Attach sales receipt to this card and retain as your proof of purchase To register your fixture please visit our website www montecarlofans com 3JVR58XXXD Series Fan cETL Model NO 3JVR58XXD 7 36 kg 16 2 lbs Owner s Guide and Installation Manual ...

Страница 2: ...building structure or the ceiling joist WARNING To reduce the risk of personal injury do not bend blade holders during installation to motor balancing or during cleaning Do not insert foreign object between rotating blades Attach the mounting bracket using only the hardware supplied with the outlet box WARNING To reduce the risk of fire or electric shock this fan should only be used with fan speed...

Страница 3: ... box is securely fastened by at least two points to a structural ceiling member a loose box will cause the fan to wobble Install the mounting bracket onto the outlet box Partially loosen the two screws on the outlet box attach the mounting bracket onto the outlet box by sliding it over the two screws as shown in the illustration Have the mounting bracket in position and tighten the set screws Inst...

Страница 4: ...jury Install ball end of downrod into mounting bracket opening Align engage slot on ball with tab on mounting bracket Warning Failure to align slot on ball with tab may result in serious injury Important If using the angle mount make sure open end of mounting bracket is installed facing the higher point of the ceiling and make sure the ceiling angle is not steeper than 20º Longer downrod may be ne...

Страница 5: ...e outlet box The splices after being made should be turned upward and pushed carefully up into the outlet box Caution The installation has to be complete before operate the fan Receiver has to be used on the fan and cannot be bypassed Attach light pan onto the plate on motor Place light pan over the lead wires from fan aligning the keyhole slots on the light pan with the preassembled screws on the...

Страница 6: ...from fan to black or blue wire from LED light fixture Attach LED light fixture onto the light pan aligning the keyhole slots on the light fixture with the preassembled screws on the light pan and twist clockwise till lock Reinstall the screw removed in step 17 Tighten all screws securely Attach light shade by locating dimples in light pan with grooves on the light shade and twist clockwise until t...

Страница 7: ...e Press the Breeze button the fan will operate at high speed 6th for 30 seconds then automatically change to 5th 4th 3rd 2nd 1st at intervals of 30 seconds and then change it from Low speed 1st to 2nd 3rd 4th 5th 6th repeat the cycle until the breeze mode is canceled Breeze mode can be erased by pressing either the power or speed control buttons Note This remote controller has auto resume function...

Страница 8: ...matically after installation it is still using the factory setting Follow the settings for Learn Mode above to reset 2 If the fan or light isn t working reset power turn the power off then turn the power back on and follow the Universal Mode or Learn Mode remote control settings 3 If two or more fans in the same remote signal range are on the same power supply they cannot be operated separately by...

Страница 9: ...ounting bracket or mounting plate are tightened securely to 4 Check that all blade holders are tightened securely to motor 5 Most fan wobble problems are caused when blade levels are unequal Check this level by selecting a point on the ceiling above the tip of one of the blades Measure this distance from blade tip to ceiling Keeping measure within 1 8 rotate the fan until the next blade is positio...

Страница 10: ...Jun 2022 ...

Отзывы: