background image

1.Check main and branch circuit fuses or circuit breakers.

2.Check line wire connections to fan and switch wire connections in switch housing.

CAUTION:  Make sure main power is turned off.

3.Make sure forward/reverse switch is firmly in up or down position.  Fan will not operate when switch

is in the middle.

4.Make sure that shipping stabilizer tabs have been removed from motor.

1.Check to make sure all screws in motor housing are snug (not over tightened).

2.Check to make sure the screws which attach the fan blade holder to the motor are tight.

3.Check to make sure wire nut connectors in switch housing are not rattling against each other or

against the interior wall of the switch housing.

CAUTION:  Make sure main power is turned off before entering switch housing.

4.Some fan motors are sensitive to signals from Solid State variable speed controls.  

DO NOT USE a Solid State variable speed control.

5.Allow "break-in" period of 24 hours.  Most noises associated with a new fan will disappear after this

period.

1.Make sure that the ridge of the canopy engages the notch in the downrod ball.  (See illustration in

Step #6 of Downrod Mount installation).

2.Check that all blades are screwed firmly into blade holders.

3.Check that all blade holders are tightened securely to motor.

4.Make sure that canopy and mounting bracket are tightened securely to ceiling junction box and junc-

tion box is mounted firmly to ceiling joist.

5.Most fan wobble problems are caused when blade levels are unequal. Check this level by selecting a

point on the ceiling above the tip of one of the blades. Measure this distance from blade tip to ceilng.

Keeping measure within 1/8", rotate the fan until the next blade is positioned for measurement. Repeat

for each blade. If all blade levels are not equal, you can adjust blade levels by the following procedure.

To adjust a blade tip down, insert a washer (not supplied) between the blade and blade holder at the

screw closest to the motor. To adjust a blade tip up, insert washer (not supplied) between the blade and

blade holder at the two screws farthest from the motor.  Reverse the position of the washer if blades

mount from top of blade.

6.If blade wobble is still noticeable, interchanging two adjacent (side by side) blades can redistribute

the weight and possibly result in smoother operation.

1.Check blue wire from fan to make sure it is connected to hot wire from house.

2.Check for loose or disconnected wires in fan switch housing.

3.Check for loose or disconnected wires in light kit.

4.Check for faulty light bulbs.

WARNING: Over lamping the fan will result in the fan lights shutting down until

the proper wattage of bulbs are installed. Reset the lights by turning off the wall

switch, breaker,or by remote. Replace bulbs with the correct wattage bulbs, turn the power

on.

CAUTION:  Make sure main power is turned off before entering switch housing and/ or

canopy.

WARNING: Before attempting to replace the fuse make sure the main power is turned off to

the fan. Replace only with a 3 amp fuse. (Fuse is inside the canopy on the blue wire to

remote receiver, push and twist the cap to open the fuse case).

2. If fan sounds noisy:

1. If fan does not start:

3. If fan wobbles:

4. If light does not work:

T

ROUBLE

S

HOOTING

If you have difficulty operating your new ceiling fan, it may be the result of incorrect assembly, installation, or wiring. In

some cases, these installation errors may be mistaken for defects. If you experience any faults, please check this Trouble

Shooting Chart. If a problem cannot be remedied, or you are experiencing difficulty in installation, please call our

Customer Service Center at the 

number printed on your parts list insert sheet. 

Warning: Before servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting

means to prevent power from being switched on accidentally.  When the service disconnecting means cannot

be locked, securely fasten a prominent warning device, such  as a tag, to the service panel.

Trouble

Suggested Remedy

Customer Service Center:

301 West Washington St.

Riverside,NJ 08075

1-800-519-4092

www.montecarlofans.com

Содержание 3AXR52XX3-L Series

Страница 1: ...Ceiling Fan Installation Instructions For 3AXR52XX3 L Series Fans READ AND SAVE THESE INSTRUCTIONS Total fan weight with light kit OWNER S MANUAL 10 1kgs 22 3lbs...

Страница 2: ...nt manufacturer s guideline safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers...

Страница 3: ...y 15 Set dip switches on the Remote T ransmitter and Remote Receiver to the same settings This must be done so the units will communcate properly If you have other fans you can set to control from one...

Страница 4: ...sing without the light provided to the fan with the 3 hex nut screws by using the hex nut driver provided Shown above Tighten securely 27 Connect plug from fan to plug from light fixture 20 Install th...

Страница 5: ...Install wall control unit to outlet box using machine screws provided 30 WALL MOUNT INSTALL Attach front cover to wall control with screws provided Snap battery cover in place 31...

Страница 6: ...ight dimmer The light will cycle from bright to dim to bright until button is released Light will maintain last setting if turned off FORWARD REVERSE Depress rev button allow a few seconds for remote...

Страница 7: ...e motor To adjust a blade tip up insert washer not supplied between the blade and blade holder at the two screws farthest from the motor Reverse the position of the washer if blades mount from top of...

Отзывы: