background image

3

© 2018 Monte Carlo Fan Company

10/2018

1

2

3

4

5

6

ON

OFF

ON

OFF

Before you begin installing the fan, Switch 

power off at Service panel and lock 

service disconnecting means to prevent 

power from being switched on 

accidentally. When the service 

disconnecting means cannot be locked, 

securely fasten a warning device, such  

as a tag, to the service panel.

Use AC 120V/60HZ power supply 

only.

Before installing this fan make sure the 

outlet box is properly installed to the 

house structure. To reduce the risk of 

fire, electric shock, or personal injury, 

mount to outlet box or supporting system 

acceptable for fan support. 

(Mounting must support at least 35 lbs.)

Use metal outlet box suitable for fan 

support and use only the screws provided 

with the outlet box  (must support 35 lbs). 

Before attaching fan to outlet box, ensure 

the outlet box is securely fastened by at 

least two points to a structural ceiling 

member (a loose box will cause the fan to 

wobble). Remove the two outlet box 

screws provided with the box, aligning 

the holes of the mounting bracket with 

the holes of the outlet box. Reinstall the 2 

outlet box screws securely.

Remove the set screws from Yoke. Keep 

screws.

Remove the top housing. 

Insert blades (

the 3 blades with a label 

“This side up”

) into the top slots on 

flywheel.

Note

: Make sure the side with a label 

“This side up” is installed upward.

 

Mounting bracket

 

Set screw

Yoke
Top housing

Top slot

Bottom slot 

Blade

This side up

This 

side 

up

This side up

This side up

Top housing

Содержание 3AMR60

Страница 1: ...ATE OF PURCHASE MODEL NUMBER RETAILER NAME RETAILER ADDRESS Attach sales receipt to this card and retain as your proof of purchase To register your fixture please visit our website www montecarlofans...

Страница 2: ...t Remove Knockouts In The Outlet Box Mount the secondary support safety cable through the reserved nail screw hole on the outlet box to the building structure or the ceiling joist Attach the mounting...

Страница 3: ...t 35 lbs Use metal outlet box suitable for fan support and use only the screws provided with the outlet box must support 35 lbs Before attaching fan to outlet box ensure the outlet box is securely fas...

Страница 4: ...n step Align the holes on blade with the screw holes on the bracket inside fan housing and install the blades with set screws provided Tighten the set screws securely Note The screw holes on the brack...

Страница 5: ...ll them will result in serious injury For Canadian installation and for USA fan and light kit combinations over 35 lbs in both flush and downrod modes the safety cable must be installed into the house...

Страница 6: ...nductor on the other side of the outlet box The splices after being made should be turned upward and pushed carefully up into the outlet box Lift canopy up aligning its keyhole slot with the preassemb...

Страница 7: ...pan Save screws for later use Attach LED light fixture onto the light pan aligning the holes on the LED light kit with the screw holes on light pan Reinstall the screws removed in step 25 Tighten all...

Страница 8: ...te control transmitter and install battery battery provided Replace the cover Note Use 2 1 5V AAA battery Note If not using for long period of time remove battery to prevent damage to remote transmitt...

Страница 9: ...ction the fan and light If the fan with light will maintain the last setting if power is turned off Tips for end users 1 If your fan is operated automatically after installation and power on it is bec...

Страница 10: ...plate are tightened securely to 4 Check that all blade holders are tightened securely to motor 5 Most fan wobble problems are caused when blade levels are unequal Check this level by selecting a point...

Страница 11: ...Oct 2018...

Отзывы: