47
balanced XLR
FEMALE connector
balanced XLR
MALE connector
balanced XLR
FEMALE socket
balanced XLR
MALE socket
1 GND
Ground
2 +
Hot
3 -
Cold
(IEC 268 standard)
2
1
3
1
2+
3-
1
2+
3-
LINK
IN
SUB OUT
1
2
3
4
User
Preset
Both = Enter
UP
DOWN
VOL.
Sub
2
1
sig
clip
thw
prot
3.3 - SYSTEM WIRING
AC mains connection
-
Make sure that the ac line voltage value corresponds to the one indicated
on rear panel.
-
Connect the mains supply cable to a socket fitted with a proven ground
contact.
3.3.1 - Wiring of signal
cables
The input socket IN (4) and the LINK socket (5) are XLR 3 pole connectors,
female (IN) and male (LINK).
They are wired according to IEC 268 (AES1492) standards:
pin 1 = ground, pin 2 = hot (+), pin 3 = cold (-).
The SUB OUT
socket is an
XLR 3 pole connector
male
Use only screened cables (signal cables) of suitable size and quality.