58
Wiring diagram for remote control management.
No.
SYMBOL
DESCRIPTION
1
V+
Generic Symbol indicating the positive pole or the phase (P) of the power
source.
2
0V
Generic symbol indicating the negative or neutral (N) pole of the power
source.
3
PE
Earthing symbol.
4
S1
Command button of the Remote Control Coil.
5
KA1
Auxiliary Relay for managing the power supply of the Remote Control
Coil.
6
REMOTE
CONTROL
Remote Control Coil / Electromagnet in the Speed Governor.
NOTE:
The supply voltage of the auxiliary relay (KA1) does not necessarily need to be the same as
the supply voltage of the Remote Control Coil.
Tab.5
Fig. 15
OPERATING PRINCIPLE
The S1 button allows you to pull out the pin of the Remote Control Coil in the
speed governor.
The S2 button allows you to restore the contact with Electrical Reset once the
speed governor has been activated.
Press and hold the S1 button while performing the verification test on the Speed
governor during the inspection; this forces the speed governor to activate, thus
triggering the respective electrical contact. Once the test is complete, press the S2
button to reset the speed governor and the respective electrical contact.