6. INSTALLATION AND FIXING
The speed governor must be installed in a building or in a closed travel com-
partment.
Do not use in an explosive atmosphere. Room temperature must range between
0°C e +40°C (unless expressly agreed/authorised).
Assembly and installation must be carried out with great care by qualified and
trained personnel. The manufacturer cannot be held responsible for damage
caused by incorrect assembly or incorrect installation. Before starting work,
make sure that adequate lifting and handling equipment is available. All fixing
points specified by the manufacturer must be used.
!
!
Check the rotating direction:
the speed governor can be on car side or coun-
terweight side. The arrow on the governor (Fig. 7) must be in the engagement
direction of the safety gear.
6.1 I
nstallation surface
- F
ixing
The speed governor is suitable for being used both with room or without room;
it can be installed flat or overturned (in the dedicated versions). If it is overtur-
ned make sure that the fixing is suitable to the intervention force.
The installation surface must be uniform, level and horizontal. The levelling to-
lerance is 0.2 mm. The installation surface must be rigid and robust enough to
withstand the forces involved.
Pay special attention to prevent shocks to the governor.
Place the unit on the installation surface and secure it. Do not force or hit the
fixings to position them; this could damage the governor.
Flat installation
Overturned installation
Fig. 8
Содержание RQ 200
Страница 2: ...www montanarigiulio com www montanarigiulio com Pag Auf S 39...
Страница 12: ...48 Narrow base Fig 2 RQ RQ A Standard base Fig 3 A A RQ RQ A...
Страница 13: ...49 www montanarigiulio com ENGLISH SPEED GOVERNORS RQ A RQ D P D P...
Страница 31: ...67 www montanarigiulio com ENGLISH SPEED GOVERNORS RQ A RQ 7 8 Protective cover Fig 23 Fig 24...