6
THIS BROILER IS DESIGNATED FOR USE WITH A GAS PRESSURE
REGULATOR. THE REGULATOR SUPPLIED WITH THIS UNIT MUST
BE USED.
G20 Natural Gas:
This gas pressure regulator is factory adjusted for
6.0” W.C. manifold pressure. The rated inlet pressure to the regulator is
1/2 psig (3.45 kPa).
G31 Propane Gas:
This gas pressure regulator is factory adjusted for
10.0” W.C. manifold pressure. The rated inlet pressure to the regulator is
1/2 psig (3.45 kPa)
GAS PRESSURE REGULATOR
Locate the gas pressure regulator external to the Salamander broiler as near to
the unit as possible. The gas pressure regulator must be located out of the heat
zone to prevent damage to the regulator.