Installation and Wiring Instructions for the Multi Room Extract Units. 

 
 

      IMPORTANT: 

READ THESE INSTRUCTIONS BEFORE COMMENCING THE INSTALLATION 

 

 

Do not install this product in areas where the following may be present or occur: 

 

Excessive oil or a grease laden atmosphere. 

 

Corrosive or flammable gases, liquids or 

vapours. 

 

Subject to direct water spray from hoses. 

 

Ambient temperatures higher than 40°C 
and lower than -20°C. 

 

Possible obstructions that may hinder 

access to or removal of the unit. 

 

All wiring must be in accordance with the current IEE wiring regulations BS7671, or appropriate standards 
of your country. Installation should be inspected and tested by a suitably qualified person after 

completion. 

 

Ensure the mains supply (voltage, frequency and phase) complies with the rating label. 

 

The unit should be provided with a local double pole fused spur fitted with a 3A fuse having a contact 

separation of at least 3mm.  

 

This appliance incorporates an earth connection for functional purposes only  

 

Precautions must be taken to avoid the back-flow of gases into the building from the open flue of gas or 
other fuel-burning appliances. 

 

This appliance is not intended for use by persons (including children) with reduced physical, sensory or 

mental capabilities, or lack of experience and knowledge, unless they have been given supervision or 
instruction concerning use of the appliance by a person responsible for their safety. 

 

Young children should be supervised to ensure that they do not play with the appliance. 

 

Cleaning and user maintenance shall not be made by children 

 

The installer is responsible for the installation and electrical connection of the unit on site. It is the 
responsibility of the installer to ensure that the equipment is safely and securely installed and left onl y 

when mechanically and electrically safe. 

 

All regulations and requirements must be strictly followed to prevent hazards to life and property, both 
during and after installation, and during any subsequent servicing and maintenance. 

 

Certain applications may require the installation of sound attenuation to achieve the sound levels required. 

 

The unit must not be connected directly to a tumble drier. 

 

The exhaust grille should be located at least 600mm away from any flue outlet.  

 

This product and associated duct installation should be carried out in accordance with the Domestic 

Ventilation Compliance Guide. 

 
 

 

 
 

 

 
 

 

 
 

 

 

Содержание MON-MEVDC400

Страница 1: ...on co uk monsoon domestic energysaver range mev energysaver systems PLEASE READ THIS QUICK START GUIDE IN CONJUNCTION WITH THE ILLUSTRATIONS PLEASE SAVE THIS QUICK START GUIDE IPX2 Quick Start Guide M...

Страница 2: ...gas or other fuel burning appliances This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unle...

Страница 3: ...1 2 If you need to use flexible ducting make sure that it is fully extended and not crushed sagging or torn 1 3 Try to minimize the use of diffusers valves by having similar length duct runs to the i...

Страница 4: ...his document for details 4 The switched live output 230Vac from any other switch or controller such as a simple latching pullcord or push button switch humidistat or PIR detector can be connected to t...

Страница 5: ...inputs 6 If the unit being commissioned is not fitted with the relevant hardware the associated menu options will not be available SERVICING MAINTENANCE WARNING THE FAN AND ANCILLARY CONTROL EQUIPMENT...

Страница 6: ...purge Purge threshold 1400 1800 PPM 1500 A1LA Analogue 1 low action Low Normal Boost or Purge speed Low A1HA Analogue 1 high action Low Normal Boost or Purge speed Purge A1tL Analogue 1 low threshold...