background image

INSTALLATION 

INSTRUCTIONS

30”, 36” and 48”

Professional Vent Hood

MONOGRAM.COM

Содержание ZV36SSJSS

Страница 1: ...INSTALLATION INSTRUCTIONS 30 36 and 48 Professional Vent Hood MONOGRAM COM ...

Страница 2: ...ARE REQUIRED FOR PROPER INSTALLATION WARNING To reduce the risk of fire or electrical VKRFN GR QRW XVH WKLV UDQJH KRRG ZLWK DQ H WHUQDO VROLG VWDWH VSHHG FRQWURO GHYLFH Q VXFK DOWHUDWLRQ from original factory wiring could result in damage to the unit and or create an electrical safety hazard WARNING 72 5 8 7 5 6 2 5 75 6 2 25 1 85 72 3 56216 2 6 59 7 2 2 1 Installation work and electrical wiring m...

Страница 3: ...TXH H WHUQH 7RXWH modification de ce type du branchement d usine peute endommager l appareil ou créer un risque de choc électrique AFIN DE RÉDUIRE LE RISQUE D INCENDIE N UTILISEZ QUE DES CONDUITS MÉTALLIQUES AVERTISSEMENT 1 5e 8 5 5 648 1 1 6 e 752 87 216 28 6 6685 6 8 3 56211 6 9 8 5 63 7 5 48 68 7 L installation et le câblage électrique doivent être effectués SDU XQH RX SOXVLHXUV SHUVRQQHV TXDOL...

Страница 4: ...Cualquier alteración del cableado original de fábrica podrá producir daños en la unidad y o crear un riesgo sobre la seguridad eléctrica ADVERTENCIA 1 5 8 5 5 6 2 1 1 26 6 5 6 e 75 6 2 6 21 6 62 5 3 5621 6 803 21 2 6 8 17 Ŷ O WUDEDMR GH LQVWDODFLyQ HO FDEOHDGR HOpFWULFR deberán ser realizados por una persona s FDOLILFDGD GH DFXHUGR FRQ WRGRV ORV FyGLJRV HVWiQGDUHV DSOLFDEOHV LQFOX HQGR FRQVWUXFFLR...

Страница 5: ...DWLRQV 9 6WHS QVWDOO RRG 2QWR DOO 6WHS QVWDOO RRG 2QWR DOO 12 12 6WHS QVWDOO RRG 7R 6RIILW 2U HQHDWK DELQHWV 6WHS QVWDOO RRG 7R 6RIILW 2U HQHDWK DELQHWV 11 11 6WHS RQQHFW XFWZRUN 6WHS RQQHFW XFWZRUN 12 12 6WHS RQQHFW OHFWULFDO 6WHS RQQHFW OHFWULFDO 12 12 6WHS QVWDOO XFW RYHUV 6WHS QVWDOO XFW RYHUV 12 12 6WHS QVWDOO LOWHUV 6WHS QVWDOO LOWHUV 13 13 6WHS QVWDOO PSOHPHQW 5RGV 6WHS QVWDOO PSOHPHQW 5RGV...

Страница 6: ...s 4 Allen Screws and 4 Stand offs Heat Lamp 2 with 48 models Monogram Logo Nameplate 2 Knobs HARDWARE PACKAGE Locate and check contents Screws shown actual size 6 Phillips head screws to secure hood to the wood support 2 secured to wood support 2 3 16 hollow wall anchors with screws to secure hood to the wall at the bottom 6 screws to secure the wood support and the hood to the wall 2 flat washers...

Страница 7: ...t by UHYLHZLQJ WKH VHFWLRQ QDPHG 3DUWV 3URYLGHG LQ WKH Installation Instructions Loosen the screws holding the wood support to the back of the hood Remove wood support Keep wood support and screws These will be used to mount the hood to the wall XOO LQVSHFW DQG FRQILUP WKDW DOO WDSH DQG SDFNLQJ material has been removed from the hood and transition duct with damper TOOLS AND MATERIALS REQUIRED NOT...

Страница 8: ...tion 30 MIN 36 MAX OPTIONAL DUCT COVER ACCESSORIES Standard decorative duct covers are available in DQG KHLJKWV XFW FRYHUV PD EH VWDFNHG LQ YDULRXV FRPELQDWLRQV WR FRQFHDO WKH GXFWZRUN running from the top of the hood to the ceiling HIRUH RX EHJLQ RX VKRXOG GHWHUPLQH WKH installation height of the hood and order the correct size duct cover The duct covers should be ordered at the same time as the ...

Страница 9: ...ne duct cover may be required 4 XFW FRYHUV PD EH VWDFNHG LQ YDULRXV FRPELQDWLRQV to reach ceiling heights Actual Ceiling Height Possible Hood Installation Height 6 Duct Covers 12 Duct Covers 7 11 35 1 8 0 8 0 30 36 1 1 8 1 31 1 8 2 32 1 8 4 33 1 8 4 34 1 8 5 35 1 8 6 8 6 30 36 1 1 1 8 7 31 1 1 8 8 32 1 1 8 9 33 1 1 8 10 34 1 1 8 11 35 1 1 9 0 9 0 30 36 1 2 1 9 1 31 2 9 2 32 2 9 3 33 2 9 4 34 2 9 5...

Страница 10: ... or soffit Stack one or more duct covers over the top of the hood to reach your ceiling height POWER SUPPLY IMPORTANT 3OHDVH UHDG FDUHIXOO WARNING 25 3 5621 6 7 7 6 33 1 0867 3523 5 5281 AVERTISSEMENT 3285 9275 3527 7 21 3 56211 7 33 5 2 7 Ç75 255 7 0 17 0 6 TERRE ADVERTENCIA 3 5 68 6 85 3 5621 67 752 20e67 2 5È 67 5 8 0 17 21 7 2 7 55 Remove house fuse or open circuit breaker before beginning ins...

Страница 11: ...erline of a 10 1 2 hole on the ceiling or soffit by measuring 6 from the wall HOUSE WIRING LOCATION 7KH MXQFWLRQ ER LV IDVWHQHG WR WKH EDFN RI WKH KRRG RQ the right side The recessed back side of the hood provides a large DUHD IRU WKH KRXVH ZLULQJ WR H LW WKH ZDOO DQG EH URXWHG WR WKH UHDU NQRFNRXW DQG MXQFWLRQ ER 5HPRYH MXQFWLRQ ER FRYHU DQG NQRFNRXW QVWDOO VWUDLQ relief Alternate Knockout Locati...

Страница 12: ...ort until they protrude 1 4 forward This 1 4 gap will provide clearance to hang the hood Use duct tape to seal the transition duct connection Check to be sure the damper moves freely Hang Hood On Wood Support Lift the hood and hold close to the installation location Route house wiring through the knockout and into the MXQFWLRQ ER 3ODFH WKH KRRG RYHU WKH ZRRG VXSSRUW H VXUH WKH mounting screws enga...

Страница 13: ...nting to the underside of a cabinet with a UHFHVVHG ERWWRP LQVWDOO VKLPV WR ILOO WKH JDS Drive mounting screws into the studs until they protrude 1 4 The 1 4 gap will provide clearance to engage the keyhole slots in the top of the hood Lift hood to installation position Locate house wiring and route through the knockout from the back or top of the hood Lift hood onto mounting screws Slide back aga...

Страница 14: ...RXQG ZLUH D JURXQG PXVW EH SURYLGHG E WKH LQVWDOOHU KHQ KRXVH ZLULQJ LV DOXPLQXP EH VXUH WR XVH 8 DSSURYHG DQWL R LGDQW FRPSRXQG DQG aluminum to copper connectors AVERTISSEMENT Si le câblage électrique de la PDLVRQ Q HVW SDV FRQVWLWXp GH ILOV DYHF XQ ILO GH WHUUH OH ILO de terre doit être ajouté par l installateur Lorsque le câblage HVW HQ DOXPLQLXP DVVXUH YRXV G XWLOLVHU XQ FRPSRVp DQWLR GDQW HW ...

Страница 15: ...ROORZ WKH VDPH SURFHGXUH RQ WKH RSSRVLWH VLGH Install knobs line up the flat on the shaft with the flat in the knob hole WWDFK 0RQRJUDP QDPHSODWH EDGJH 8VH WKH template on page 14 for alignment of the nameplate Cut out the template and tape it onto the hood front surface and verify the template is aligned with the left side of the hood and within the upper and ORZHU HGJH RI WKH IURQW VXUIDFH 3UDFW...

Страница 16: ...16 31 2000859 Rev 0 Notes ...

Страница 17: ...31 2000859 Rev 0 17 Notes ...

Страница 18: ... be worn RU 0RQRJUDP ORFDO VHUYLFH LQ RXU DUHD YLVLW monogram com or call 1 800 444 1845 NOTE 3URGXFW LPSURYHPHQW LV D FRQWLQXLQJ HQGHDYRU DW 0RQRJUDP SSOLDQFHV 7KHUHIRUH PDWHULDOV DSSHDUDQFH and specifications are subject to change without notice 31 2000859 Rev 0 10 20 GEA Printed in Italy ...

Отзывы: