 STEP 12  INSTALL AUTOFILL PITCHER ASSEMBLY 

(Some Refrigerator Models)

Ŷ

  Locate the AutoFill pitcher cover on the left side of the 

refrigerator’s interior. Remove T20 Torx screw holding 
the cover in place towards the rear of the cover. Retain 
this screw for attachment of AutoFill assembly. 

Ŷ

  Slide the cover forward to remove. This reveals an 

electrical connector and a water tube.

Ŷ

  Remove the AutoFill assembly from the box. Connect 

the 4 pin connector from the AutoFill assembly to the 
connector in the compartment wall.

Ŷ

  Ensure that the locking tab on the connector is fully 

engaged.

Ŷ

  Connect the water line fitting from the AutoFill 

assembly to the water tube located in the 
compartment. Ensure the water tube is firmly 
connected and will not easily become unattached. 
Water tube should be inserted to the tubing mark.

Ŷ

  Conceal wires and tubing inside the wall compartment 

and place the AutoFill wall assembly onto the forward 
end of the mount until flush with the interior wall of the 
refrigerator. Slide the assembly toward the back wall 
until mounting screw hole is visible.

Ŷ

  Secure AutoFill assembly with the T20 Torx screw 

removed earlier.

Ŷ

  

Ensure supply water is connected to the refrigerator 
before proceeding further.

Ŷ

  Align the pitcher lid to the dispenser guide and slide 

the pitcher toward the back of the refrigerator until it 
stops. There may be up to a 5 second response time 
before water starts to fill the pitcher. 

Ŷ

  Water will fill the pitcher until it reaches a specified 

level and will then shut off. It is normal for the water 
level to be below the top of the pitcher.

NOTE: 

After installing the AutoFill pitcher, run 2 gallons 

of water (approximately 5 full pitchers) through the 
AutoFill dispenser to remove air from the system. 
A newly installed filter cartridge will cause water to 
spurt and dribble until the air is out of the system. It is 
normal for water to appear discolored during the initial 
system flush. Water color will return to normal after the 
first minutes of dispensing. Wash the AutoFill pitcher 
following the initial flush before using.

NOTE: 

Do not place the pitcher in the dispenser guide 

before the water connection is made to the refrigerator.

Screw

AutoFill 
Assembly

Mount 
Compartment

Screw

Cover

Содержание ZIR300NPKII

Страница 1: ...Installation Instructions 18 and 24 Built In Column Freezers 24 and 30 Built In Column Refrigerators...

Страница 2: ...appliance with the anti tip system WARNING Explosion Hazard Keep flammable materials and vapors such as gasoline away from appliance Failure to do so can result in fire explosion or death WARNING To...

Страница 3: ...rt Icemaker 29 Step 12 Install AutoFill Pitcher Assembly 30 Instructions for Single Integrated Installation 31 The Installation Space 32 Tools Hardware Materials 33 Grounding the Unit 33 Flooring 33 S...

Страница 4: ...SIDE VIEW 83 3 8 211 77 C 83 1 4 211 46 A D 4 10 16 TOP VIEWS DOOR OPEN 90 DOOR OPEN 115 E F B 4 10 16 Minimum to a Wall B 15 38 1 Minimum to a Wall 16 5 41 9 on 30 models Dimensions 18 Models 24 Mode...

Страница 5: ...h 25 deep opening Reversing the Door Swing all installation types Making a refrigerator LH swing and freezer RH swing Instructions for Stainless Steel Door Panel Installation all installation types In...

Страница 6: ...6 31 49133 1 Instructions for Dual Integrated Installation New construction installation with 25 deep openings...

Страница 7: ...e 1 4 O D copper tubing or QuickConnect kit WX08X10006 between the cold water line and water connection location long enough to extend to the front of the unit 8 2 4m Installation of an easily accessi...

Страница 8: ...t a fully loaded refrigerator or freezer or approximately 1 200 lbs per unit NOTE Protect the finish of the flooring NOTE Not recommended for installation on carpeted flooring GROUNDING THE UNIT The p...

Страница 9: ...cet long enough to clear the line of water Install a shut off valve between the water valve and cold water pipe in a basement or cabinet The shut off valve should be located where it will be easily ac...

Страница 10: ...hem to the left side of the case between the 2 units 2 on the upper section of the case wall and 2 on the lower Install adhesive heater on the outside of the unit to the left side of the case Install...

Страница 11: ...ip bracket should be mounted against the back wall or up to 27 68 6 cm maximum from front of opening Use floor mounting method if the bracket is not against a wall bracket hardware is provided for mou...

Страница 12: ...floor approximately 3 to the left of the anti tip bracket Apply tape about every 5 toward the front of the opening tape will prevent the unit from rolling over the waterline during installation Do no...

Страница 13: ...nut to the union Turn on the water to check for leaks SmartConnect Tubing NOTE The only GE Appliances approved plastic tubing is supplied in the SmartConnect Refrigerator Tubing kits Do not use any o...

Страница 14: ...k the unit back pull the anti tip strap tight Secure the strap in the front of the unit This process should be completed for each unit Secure the strap in the front of the unit by replacing the screw...

Страница 15: ...ore than 1 you will damage the front leveling legs and the rear leveling wheels Hex nut adjusts rear wheels Open end wrench adjusts front leveling legs STEP 9 FINAL EXTERNAL UNIT PREPARATION FOR FLUSH...

Страница 16: ...power switch to OFF Top wire basket must be removed to access the icemaker power switch When the freezer has been connected to the water supply set the power switch to ON Throw away the first full bu...

Страница 17: ...e refrigerator Slide the assembly toward the back wall until mounting screw hole is visible Secure AutoFill assembly with the T20 Torx screw removed earlier Ensure supply water is connected to the ref...

Страница 18: ...18 31 49133 1 Instructions for Dual Retro Fit Installation Existing construction installation with 24 deep openings that are 41 1 2 or 47 1 2 wide...

Страница 19: ...learances These units are equipped with a 2 position door stop The factory set 115 door swing can be adjusted to 90 if clearance to adjacent cabinets or walls is restricted For a 90 door swing allow 4...

Страница 20: ...will not run often enough to maintain proper temperatures Do not install the refrigerator freezer where temperatures will go above 100 F 37 C It will not perform properly Do not install the refrigerat...

Страница 21: ...water pressure must be between 40 and 120 p s i 275 827 kPa Shut off the main water supply Turn on the nearest faucet long enough to clear the line of water Install a shut off valve between the water...

Страница 22: ...etal case Ensure the heater connector cord is toward the bottom of the unit when installed Remove the left access cover by removing 4 1 4 hex screws The cover is located at the outside lower left side...

Страница 23: ...hardware is provided for mounting into wood steel studs and concrete Measure and mark from the LH side of the opening per the table above depending on the size of the LH unit you are installing Measu...

Страница 24: ...ring installation Do not tape near the cabinet front in order to keep tape hidden under the unit Route the strapping coiled up at the back of the unit through the anti tip bracket 1 Cut the wire tie h...

Страница 25: ...cord green ground screw 3 Install the power cord strain relief Replace rear access cover Make sure the power cord and ground wire are properly routed through the access cover cut out Repeat all steps...

Страница 26: ...s under pressure at all times Other types of plastic may crack or rupture with age and cause water damage to your home Insert the molded end of the tubing into the refrigerator or freezer connection T...

Страница 27: ...pushed back As you walk the unit back pull the anti tip strap tight Secure the strap in the front of the unit This process should be completed for each unit Secure the strap in the front of the unit b...

Страница 28: ...nt of the unit To level the back of the unit turn the 7 16 hex nut located above the front wheels Turn clockwise to raise or counterclockwise to lower the unit For front leveling use a 7 16 open end w...

Страница 29: ...aker set the power switch to OFF Top wire basket must be removed to access the icemaker power switch When the freezer has been connected to the water supply set the power switch to ON Throw away the f...

Страница 30: ...efrigerator Slide the assembly toward the back wall until mounting screw hole is visible Secure AutoFill assembly with the T20 Torx screw removed earlier Ensure supply water is connected to the refrig...

Страница 31: ...31 31 49133 1 Instructions for Single Integrated Installation New construction installation with 25 deep openings...

Страница 32: ...1 2 8 9cm finished return matching cabinet exterior is recommended on interior on all sides and top at front of opening Installations with 4 10 2 cm or less between units require Heater Kit ZUGC 18 I...

Страница 33: ...ill not run often enough to maintain proper temperatures Do not install the refrigerator freezer where temperatures will go above 100 F 37 C It will not perform properly Do not install the refrigerato...

Страница 34: ...nough to clear the line of water Install a shut off valve between the water valve and cold water pipe in a basement or cabinet The shut off valve should be located where it will be easily accessible T...

Страница 35: ...bracket Apply tape about every 5 toward the front of the opening tape will prevent the unit from rolling over the waterline during installation Do not tape near the cabinet front in order to keep tape...

Страница 36: ...lug unit into the outlet in the wall Loosen the strap by removing a Phillips head screw from the top strap bar and the large tensioner 1 4 allen screw to allow the strap to move freely during installa...

Страница 37: ...nit turn the 7 16 hex nut located above the front wheels Turn clockwise to raise or counterclockwise to lower the unit For front leveling use a 7 16 open end wrench Adjust height of unit to match inst...

Страница 38: ...zer may take 12 24 hours to begin making ice The icemaker will produce seven cubes per cycle approximately 15 cycles in a 24 hour period depending on freezer compartment temperature room temperature n...

Страница 39: ...the refrigerator Slide the assembly toward the back wall until mounting screw hole is visible Secure AutoFill assembly with the T20 Torx screw removed earlier Ensure supply water is connected to the...

Страница 40: ...40 31 49133 1 Reversing the Door Swing This step can be done for all installation types...

Отзывы: