91
Terminal Operation
Add Value Disabled
This message occurs when an add value card has been swiped on the terminal, but the add value
mode has not been enabled on that device.
Other Messages
Unknown Term Flt
An unexpected and unhandled fault has occurred. The terminal does not know what the problem is.
This error should hardly ever occur in practice and has been put into the terminal as a last resort
procedure.
Bad Mac Number
The terminal's MAC address has been corrupted.
Memory Error
A problem has occurred with the contents of the terminal's memory. It can be a problem as simple
as a firmware upgrade erasing a portion of memory (which the terminal will easily recover from) or
as fatal as a faulty memory chip in the terminal.
RTC Clock Failed
The Real Time Clock has failed. The RTC is responsible for keeping time on the terminal. This may
be caused by a hardware failure.
Unused Op Code
The terminal has tried to execute an invalid command. Sometimes caused by corrupt packets
received on the network. This should very seldomly occur.
NMI trig Error
Caused by internal corruption of memory or program stack. The terminal should recover from this
error automatically.
Overflow Error
An error has occurred in memory. The terminal should recover from this error automatically.
Содержание MB206
Страница 1: ...MB206 Terminal Reference Guide From Version 6 58 02 www monitorbm com ...
Страница 70: ...Version 6 Terminal Menu System Options 64 3 The terminal then resolves it to an IP address ...
Страница 71: ...65 Terminal Interface Cables Terminal Interface Cables Toshiba Copier Canon Copier Konica Copier Ricoh Copier ...
Страница 73: ...67 Terminal Interface Cables B W Copier Type 2 ACT812 Retail Handset ...
Страница 74: ...Terminal Interface Cables 68 TMSR Barcode Mag Card Reader ...