7.  OPERATION 

 
To operate the Crypto-Lock, enter the valid 
3, 4, 5, or 6 digit PIN code on the keypad.  
When the valid PIN code is entered, the 
green LED on the Keypad will illuminate 
and the lock will release. 
 
The Keypad has a built-in visitor 
annunciator button. Pressing the # key 
causes a horn to sound in the Control 
Panel.  If an external sounding device is 
connected as shown in Figure 5-1 it will 
also sound when this button is pressed. 
 
If an incorrect PIN code is entered the 
system will enter a penalty mode and will 
not recognize any digits for a time period of 
from 5 to 60 seconds.  If five successive 
invalid PINs are entered the penalty time is 
set to 60 seconds until the valid PIN is 
entered. After the penalty time has elapsed 
the Panel will return to normal operation 

and entering the valid PIN code on the 
Keypad will release the door. 
 
The internal Release Button on the Control 
Panel can be used by an attendant to 
release the lock from a location on the 
secure side of the door. Similarly, if a 
remote release button has been installed it 
can also be used to release the door. 

 
Alarms 

Various alarms can be programmed to 
activate different horn sequences and 
activate 24Vdc output signals.  
 

 

Internal Horn and Horn Output Signal 
(T3-9) 

Table 7-1 lists the horn sequences and 
their meaning. 
 
 
 

Table 7-1, Alarm Sequences 
    Alarm 
Type 

                                   Alarm Sequences 
                        (HORN and T3-9 Output) 

Silenced by: 

Visitor  

                                     Activated by # button on keypad 

Invalid PIN 

- - - - - 

Five short 
beeps 

After five short 
beeps 

Door 
Propped 
 

____     ____     ____     ____     ____     

Long bursts 

Door closed or 
time out set by 
code *23*N* 

Forced Door 

- - - - - - - - - - - - - - - - - - - - - - - - - - - - -   Short bursts 

Valid PIN or code 
*24*0* 

Low Battery 

-               -               -               -                 Chirp every 15 

seconds 

Apply AC power 

Aux. Alarm 

_ __ _ __ _ __ _ __ _ __ _ __ _ __ _ __   Short/long 

bursts 

Door closed or 
lock released 

 
 

Содержание Crypto Lock CC-8521BN

Страница 1: ...1 Crypto Lock CC 8521BN 7 17 Access Control System INSTRUCTION MANUAL MONITEQ Inc...

Страница 2: ...2...

Страница 3: ...2 CONTROL PANEL 7 5 INSTALLATION 8 5 1 GENERAL 8 5 2 INSTALLATION PROCEDURE 8 5 3 POWER SUPPLY SETTINGS 9 6 1 PROGRAMMING 11 6 1 GENERAL 11 6 2 PROGRAMMING INSTRUCTIONS 11 6 2 1 INITIAL SETTINGS 11 6...

Страница 4: ...noring all keypad entries for 3 to 60 seconds after an invalid digit is entered Further if five or more successive invalid PINs are entered the penalty time is set to 60 seconds until the valid PIN is...

Страница 5: ...d Alarm Horn Output KEYPAD WITH STATUS LED REMOTE RELEASE BUTTON not supplied Door sensor Stand by Batteries Built in Horn and Release Buttom Ship s Central Alarm System Output Features 3 4 5 or 6 dig...

Страница 6: ...3 to 60 seconds set to 60 seconds after five invalid PIN attempts Remote release input Dry contact closure Door monitoring functions Door propped open alarm forced door alarm anti tailgating Keypad D...

Страница 7: ...rogramming codes Key Used as a delimiter for programming codes and parameters Key Used to terminate the programming mode Green LED indicator Programming mode Flashes continuously After a valid program...

Страница 8: ...the secure side of door using the four mounting holes See diagram on page 18 Note All cables passing through holes made in enclosure must be protected from chafing Route all cables to avoid the batter...

Страница 9: ...ent Greenleaf BRUTE can be damaged if powered for more than 15 seconds with unlimited current In the LIMit position up to 16A of current is available to initially open the lock but after the lock is o...

Страница 10: ...TERY GROUND HORN T3 GROUND EXT RELEASE REQUEST TO EXIT Door Switch see table above DOOR SWITCH GROUND O R G W H T O R G 24 VDC 1 2 3 4 5 6 7 8 7 8 9 10 7 8 9 1 2 3 4 5 6 10 11 GROUND LOCK SWITCH GROUN...

Страница 11: ...3 N 15 to 255 sec 0 Door Closed Door Closed Forced Door Alarm 24 N 0 Off 1 On Off Door Switch Sense 25 N See Table 6 2 PROGRAMMING INSTRUCTIONS Enter the Programming Mode by pressing the PROGRAM MODE...

Страница 12: ...ion time enter 20 N where N is from 5 to 60 seconds Anti Tailgating The Anti Tailgating mode is provided to prevent the door from being re opened a second time during the Open Duration time period Thi...

Страница 13: ...entering the valid PIN code on the Keypad will release the door The internal Release Button on the Control Panel can be used by an attendant to release the lock from a location on the secure side of...

Страница 14: ...5 1 2 and 3 The relay controlling these contacts is activated continuously when a The door switch input T3 5 and T3 6 indicates that the door is ajar and b The Lock Switch Input T3 7 and T3 8 is open...

Страница 15: ...15 CRYPTO LOCK Model CC 8421BN Keypad Mounting Template 3 5 8 4 5 8 3 4 D cable grommet Pilot holes Threaded inserts for 8 32 screw or threaded rod Keyhole for 8 screws 8 KEY PAD INSTALLATION TEMPLATE...

Страница 16: ...16...

Страница 17: ...17 9 CONTROL PANEL MOUNTING DIAGRAM 5 28 14 75 13 5 12 3 38 Mounting holes for 3 8 studs 4 places 1 4 Aluminum Mounting Bars...

Страница 18: ...18...

Страница 19: ...19...

Страница 20: ...warranty is void in cases of abuse misuse mishandling modification or repair by unauthorized persons This warranty is given in lieu of all other warranties expressed or implied Moniteq is not liable...

Отзывы: