SCH2 Technical Manual TSP016.doc Issue 3.0 – January 2005
Money Controls 2005. All rights reserved.
Page 52 of 61
24. Appendix B
24.1 Timing Parameters
Table 11: Timing Parameters:.
Nominal values are shown.
Label
Description
Value
Units
Xtal
PIC Resonator
4.0
MHz
Brate
Serial communication baud rate
9600
baud
Trxout
Receive data timeout
25
ms
Vtrip
Power-fail trip threshold ( +24V motor )
16
V
TPinit
Power-up initialisation time
600
ms
TSinit
Software reset initialisation time
< 40
ms
TMRelOn
Motor-on relay delay
25
ms
TMRelOff
Motor-off relay delay
25
ms
TMreverse
Motor reversing time
150
ms
Irelay
Motor protection relay rating ( surge )
10
A
TEESave
EEPROM data save time
17
ms
Ifuse
Absolute maximum trip current
5
A
Tlevdeb
Level sensor debounce time
2
s
Comms reply delay : Simple poll
< 2
ms
Comms reply delay : Enter PIN number ( correct )
< 2
ms
Comms reply delay : Enter PIN number ( wrong )
235
ms
Comms reply delay : Write data block
8
ms
Comms reply delay : Dispense hopper coins
< 4
ms
Comms reply delay : Request hopper status
< 2
ms
Comms reply delay : Pump RNG
< 2
ms
Comms reply delay : Request cipher key
< 2
ms
24.2 Opto Security Timing
When idle, the hopper software tests the optos on a pseudo-random basis to make a
deliberate fraud attempt much harder. The sampling period varies between 15 and 255
milliseconds. When paying out coins, the sampling period changes to between 64 and 127
milliseconds.
24.3 Hopper Initialisation
No serial communication is possible during the ‘TPinit’, ‘TRinit’ and ‘TSinit’ time.