21. Maintenance Schedule
Table 8: Maintenance Schedule
Maintenance Schedule
Every 50,000 to 100,000
depending on coin type.
Using a mild detergent on a damp cloth.
No spray solvents should be used.
Every 500,000 coins.
Replace ejector fingers and spring
Every 1,000,000 coins.
Replace adjuster plate
Expected product lifetime:
3 million coins with routine maintenance
21.1 Clearing a coin jam:
¾
Remove all coins from bowl.
¾
Remove motor assembly from base as described.
¾
Clear the jammed coin by either:
i.
Rotating the disk manually, first anti-clockwise then clockwise to free the coin
OR
ii.
Push the coin back in using another coin.
¾
Remove any debris from the disk bed assembly.
¾
Clean the exit window opto with a clean dry cloth.
¾
Re-assemble, as described.
¾
Refill and test the hopper.
22. Fault Finding and Repair
Table 9: Fault Finding and Repair.
Problem:
Check:
Cure:
Ensure coin exit is clear.
Remove blockage from coin exit.
Ensure correct coins in hopper.
Fill hopper with correct coins.
Coins fail to unjam:
Ensure no badly bent coins in
hopper.
Remove bent coin/s.
Supply fuse.
Replace fuse.
Protection device tripped.
Wait 30 seconds with supply OFF.
Motor fails to run:
Hopper has detected an opto fault.
Check EEPROM flags.
Over payout of coins:
Check opto area/coin exit area for
dirt.
Clean opto/coin exit area.
Check opto area/coin exit area for
dirt.
Clean opto/coin exit area.
Under Payout Of
Coins:
Ensure hopper contains sufficient
coins.
Refill hopper.