background image

T

HE

 

DESIGN

 

OF

 

THIS

 

HEATER

 

COMPLIES

 

WITH

 

STANDARD

 Z21.11.2 

OF

 

THE

 A

MERICAN

 N

ATIONAL

 S

TANDARDS

 I

NSTITUTE

 

AS

CERTIFIED

 

BY

 CSA I

NTERNATIONAL

.

T

HIS

 

IS

 

AN

 

UNVENTED

 

GAS

-

FIRED

 

HEATER

.  I

T

 

USES

 

AIR

 (

OXYGEN

FROM

 

THE

 

ROOM

 

IN

 

WHICH

 

IT

 

IS

 

INSTALLED

.  P

ROVISIONS

FOR

 

ADEQUATE

 

COMBUSTION

 

AND

 

VENTILATION

 

AIR

 

MUST

 

BE

 

PROVIDED

.  R

EFER

 

TO

 

C

OMBUSTION

 

AND

 V

ENTILATION

A

IR

 R

EQUIREMENTS

 

SECTION

 

OF

 

THIS

 

MANUAL

 

FOR

 

DETAILS

.

D

O

 

NOT

 

STORE

 

OR

 

USE

 

GASOLINE

 

OR

 

OTHER

 

FLAMMABLE

 

VAPORS

 

AND

 

LIQUIDS

 

IN

 

THE

 

VICINITY

 

OF

 

THIS

 

OR

 

ANY

 

OTHER

APPLIANCE

.

  

WHAT TO DO IF YOU SMELL GAS

• D

O

 

NOT

 

TRY

 

TO

 

LIGHT

 

ANY

 

APPLIANCE

.

• D

O

 

NOT

 

TOUCH

 

ANY

 

ELECTRICAL

 

SWITCH

;  

DO

 

NOT

 

USE

 

ANY

 

PHONE

 

IN

 

YOUR

 

BUILDING

.

• I

MMEDIATELY

 

CALL

 

YOUR

 

GAS

 

SUPPLIER

 

FROM

 

A

 

NEIGHBOR

S

 

PHONE

.  F

OLLOW

 

THE

 

GAS

 

SUPPLIER

S

INSTRUCTIONS

.

• I

F

 

YOU

 

CANNOT

 

REACH

 

YOUR

 

GAS

 

SUPPLIER

CALL

 

THE

 

FIRE

 

DEPARTMENT

.

WARNING:  I

F

 

THE

 

INFORMATION

 

IN

 

THIS

 

MANUAL

 

IS

 

NOT

 

FOLLOWED

 

EXACTLY

A

 

FIRE

 

OR

 

EXPLOSION

 

MAY

 

RESULT

CAUSING

 

PROPERTY

 

DAMAGE

PERSONAL

 

INJURY

 

OR

 

LOSS

 

OF

 

LIFE

.

I

NSTALLATION

 

AND

 

SERVICE

 

MUST

 

BE

 

PERFORMED

 

BY

 

A

 

QUALIFIED

 

INSTALLER

SERVICE

 

AGENCY

 

OR

 

THE

 

GAS

 

SUPPLIER

.

WARNING

WARNING

IRVF2T, IRVF3T, 

AND

 IRVF5T M

ODELS

I

NFRARED

 U

NVENTED

 R

OOM

 H

EATERS

WITH

 T

HERMOSTAT

 C

ONTROL

I

NSTALLATION

, O

PERATION

 

AND

 M

AINTENANCE

 M

ANUAL

T

HIS

 

APPLIANCE

 

MAY

 

BE

 

INSTALLED

 

IN

 

AN

 

AFTERMARKET

PERMANENTLY

 

LOCATED

MANUFACTURED

 (

MOBILE

HOME

,

WHERE

 

NOT

 

PROHIBITED

 

BY

 

LOCAL

 

CODES

.

T

HIS

 

APPLIANCE

 

IS

 

ONLY

 

FOR

 

USE

 

WITH

 

THE

 

TYPE

 

OF

 

GAS

 

INDICATED

 

ON

 

THE

 

RATING

 

LABEL

. T

HIS

 

APPLIANCE

 

IS

 

NOT

CONVERTIBLE

 

FOR

 

USE

 

WITH

 

OTHER

 

GASES

.

53D9012. Rev 1 03/03

Содержание IRVF2T

Страница 1: ...LY CALL YOUR GAS SUPPLIER FROM A NEIGHBOR S PHONE FOLLOW THE GAS SUPPLIER S INSTRUCTIONS IF YOU CANNOT REACH YOUR GAS SUPPLIER CALL THE FIRE DEPARTMENT WARNING IF THE INFORMATION IN THIS MANUAL IS NOT...

Страница 2: ...ILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM WITH THE HEATER DO NOT PLACE CLOTHING OR OTHER FLAMMABLE MATERIAL ON OR NEAR THE HEATER ANY SAFETY SCREEN OR GUARD REMOVED FOR SERV...

Страница 3: ...s are detected report this to the dealer from whom you purchased the heater and get the deficiency corrected before installing and using the heater Do not install or use a damaged or incomplete heater...

Страница 4: ...5 PARTS DIAGRAM 2 8 11 IN WC 555 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 FRONT FRONT RIGHT RIGHT SIDE SIDE LEFT LEFT SIDE SIDE TOP TOP 53D9012 Rev 1 03 03...

Страница 5: ...Hearth Plate Assembly Reflector Left Side Pntd Brace Reflector Piezo Cable Cabinet Side Left W Labels Piezo Ignitor Cabinet Top w Caution Label Pilot NAT Gas Pilot LP Gas Venturi Shield Burner Tube A...

Страница 6: ...ions of this manual The control system on this heater serves several functions It regulates the incoming gas to the correct pressure for the combustion rate required It will not regulate LP gas direct...

Страница 7: ...inches Sides 12 inches on one side of the heater 18 inches on the opposite side of the heater Top 36 inches Front 48 inches 36 MIN 36 MIN SEE NOTE 2 SEE NOTE 2 18 MIN 18 MIN SEE NOTES SEE NOTES 1 2 1...

Страница 8: ...the only model that may be installed in a bedroom If an infrared heater is installed in a bedroom it must be wall mounted Floor stand mounted heaters are prohibited in bedrooms FLOOR PROTECTION Some F...

Страница 9: ...aded joints of gas piping must be resistant to the action of liquefied petroleum gas Gas piping must be of sufficient size to provide a minimum natural gas pressure at the appliance of 7 inches water...

Страница 10: ...AS SUPPLY IN BOTTOM OF HEATER SUPPLY IN BOTTOM OF HEATER FIGURE 3 UNION SHUTOFF VALVE JOIST SEDIMENT TRAP TEE GAS SUPPLY LINE FLOOR NOTE A PLUGGED 1 8 NPT TAP MUST BE LOCATED SOMEWHERE BETWEEN THE SHU...

Страница 11: ...put rating of all gas fired appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1 000 Btu per hour 4 8m per kW of the aggregate input...

Страница 12: ...ve off carbon monoxide an odorless poisonous gas If this heater shuts off during operation do not relight it until you provide additional fresh air If permanent provisions for providing additional fre...

Страница 13: ...e not designed for use with optional blowers These blowers are the only blowers acceptable for use on these heaters The use of any other blower could adversely and dangerously affect the operation of...

Страница 14: ...into the wall as shown by Figure 5 USE HAMMER TO DRIVE ANCHOR INTO WALL USE HAMMER TO DRIVE ANCHOR INTO WALL NOTE ANCHORS ARE FOR USE IN HOLLOW NOTE ANCHORS ARE FOR USE IN HOLLOW WALLS WALL AREA BETW...

Страница 15: ...of the heater Insert two screws from the bag of fasteners through the holes in the standoffs Tighten the screws into the wall until the heater is firmly secured to the wall See Figure 6 Proceed to St...

Страница 16: ...n wall do the following Turn the gas off at the shutoff valve Loosen the four screws which secure the control s mounting bracket Item No 23 of PARTS DIAGRAM found in the upper righthand corner of the...

Страница 17: ...CE 21 After all checks are satisfactorily completed as described above turn the heater s control knob to Pilot and reinstall the heater s front panel See Figure 6 22 The heater may now be operated for...

Страница 18: ...ntrol knob cl ll not stay lit after several tries turn the gas control knob clockwise to OFF and call your service lier gas supplier ng steadily slowly turn the control knob coun and burning steadily...

Страница 19: ...minute a 3 After the pilot is lit continue to hold the control knob down for a minute and then release it The control knob nd then release it The control knob should pop back up fully and the pilot sh...

Страница 20: ...stible materials gasoline and other flammable liquids 9 Do take the necessary precautions during any pressure testing of the heater s gas supply piping system 10 Do keep children and mentally impaired...

Страница 21: ...CE The pilot gas flow is not adjustable on this heater Proper operation of the ODS Oxygen Depletion Sensitive Pilot Safety System is dependent upon the pilot gas flow rate and any attempt to adjust th...

Страница 22: ...their probable cause and solution Any adjustments and or replacements must be performed by a qualified person Do not replace any component with a different type Only use components supplied by the man...

Страница 23: ...nsequential damages so the above limitation or exclusion may not apply to you 4 This warranty applies only to the original purchaser and may not be transferred 5 This warranty applies only to a gas he...

Страница 24: ...ATTENTION APPLIANCE INSTALLER PLEASE RETURN THESE OPERATING AND INSTALLATION INSTRUCTIONS TO THE APPLIANCE FOR CONSUMER USE 53D9012 REV 1 03 03...

Отзывы: