57D0016
11
Grate
ZERO-CLEARANCE (METAL) FIREPLACE REQUIREMENTS
• The damper and grate must be removed.
• The smoke shelf, internal baffl es, screen, refractory, and metal or glass doors may be removed (if applicable).
• Installer must attach red warning plate to the inside of the fi rebox of fi replace with
screws supplied.
• Do not cut any sheet metal parts of the fi replace in which this gas fi replace insert is
installed. THIS IS STRICTLY PROHIBITED!
• If factory-built fi replace has no gas access hole(s) provided, drill a 1.5" (37.5mm) or
less through lower sides or bottom of fi rebox. You must plug the access hole with
noncombustible insulation after gas supply line has been installed.
• If your factory-built fi replace has air passages on the face for zero capabilities, DO
NOT BLOCK THESE PASSAGES!
W
ARNING
• Do not remove or alter the insulation or any structured rigid frame members (metal sides, fl oor, door frame, face of the
fi replace, etc.).
INSTALLATION
Figure 5 - Metal Fireplace Zero-Clearance Requirements
IMPORTANT:Please review the following carefully.
It is normal for inserts fabricated of steel to give off some expansion and/or contraction noises during the start up or cool
down cycle. Similar noises are found with your furnace heat exchanger or car engine.
It is not unusual for your insert to give off some odor the fi rst time it is burned. This is due to the curing of the paint and any
undetected oil from the manufacturing process.
Please ensure that your room is well-ventilated. OPEN ALL WINDOWS DURING INITIAL BURN OFF/
CURING PHASE.
Burn your insert for a least six (6) hours on “HIGH” the fi rst time you use it. Place fan in the “OFF” position during
this time.