background image

F

IREPLACE

 L

OCATION

CAUTION:   Do not install fireplace over carpeting.

This fireplace does not weigh more than large pieces of furniture and can normally be located near a load
bearing wall without requiring additional foundations or supports.  If however, the fireplace is to be trimmed
with a heavy stone or brick facing and hearth extension, be sure the supporting structure is adequate.

Figures 5 and 6 provide dimensional details of the fireplace, required spacing to combustible walls, and some
suggested fireplace locations.  When selecting a location, choose one that is away from frequently opened
doors, central heat outlets or returns, or other places where air movements may disturb the airflow around the
fireplace.  Air turbulence near the fireplace may cause smoke to spill out of the fireplace opening.

FULL PROJECTION

FULL PROJECTION

FLUSH

FLUSH

CORNER

CORNER

SIDE WALL INSTALLATION

SIDE WALL INSTALLATION

53 1/8

53 1/8

64 15/16

64 15/16

(MIN)

(MIN)

CORNER INSTALLATION

19 3/8

19 3/8

19 3/8

19 3/8

CLEARANCE

CLEARANCE

AIR SPACE

AIR SPACE

1 1/2

1 1/2

16*

16*

(MIN)

(MIN)

76 1/2

76 1/2

(MIN)

(MIN)

28

28

(MIN)

(MIN)

23 1/2

23 1/2

(MIN)

(MIN)

27 7/8

27 7/8

(MIN)

(MIN)

91 7/8 

91 7/8 

* APPLIES WHEN GLASS DOORS ARE INSTALLED

* APPLIES WHEN GLASS DOORS ARE INSTALLED

SCREENED OPENING

SCREENED OPENING

7

F

IGURE

 5

F

IGURE

 6

53D9038. Rev 1 03/03

Содержание HWB700OD

Страница 1: ...OD MODEL RESIDENTIAL AND OUTDOOR FIREPLACE INSTALLATION OPERATION AND MAINTENANCE MANUAL THIS FIREPLACE IS LISTED BY OMNI TEST LABORATORIES FOR USE WITH L SERIES CHIMNEY SYSTEM COMPONENTS 53D9038 Rev 1 03 03 ...

Страница 2: ...ilure to install operate and maintain this or any other factory built fireplace properly can result in a house fire or other occurrences that could cause deaths injuries and property damages It is very important that the persons installing and or supervising the installation of this fireplace have appropriate skills in using the tools and techniques required and reading and comprehension skills su...

Страница 3: ...reas INTENDED PRODUCT USAGE The fireplace is designed to sit directly on a combustible floor The fireplace must be installed with clearances to combustible building materials specified in this manual Only parts manufactured by Monessen Hearth Systems and labeled for use with the fireplace should be used in the installation of this fireplace except for special roof flashings that may be fabricated ...

Страница 4: ...mper When the fireplace is not in use the damper should be closed to prevent cold air form entering the chimney as well as preventing warm air in the room from escaping up the chimney NOTE It is normal for a small amount of smoke to be released from the upper portion of the fireplace the first few times you use your new fireplace This results from an oil residue on the metal Open a door or window ...

Страница 5: ...STOP MODEL LF FS 2 FIRESTOP MODEL LF FS 2 REQUIRES 17x17 FRAMING REQUIRES 17x17 FRAMING 54 54 STORM COLLAR STORM COLLAR MODEL LC CHIMNEY CAP MODEL LC CHIMNEY CAP ROOF FLASHING ROOF FLASHING MODEL 612 MODEL 612 CAUTION CAUTION DO NOT RESTRICT SIDE AIR DO NOT RESTRICT SIDE AIR INLET VENTS WITH SURROUND INLET VENTS WITH SURROUND OR TRIM MATERIALS OR TRIM MATERIALS GALVANIZED METAL STRIP GALVANIZED ME...

Страница 6: ...LLED APPLIES WHEN GLASS DOORS ARE INSTALLED SAMPLE INSTALLATION FOR REFERENCE ONLY EXTERIOR FINISH EXTERIOR FINISH MA MATERIALS TERIALS REMO REMOVED FOR CLARITY VED FOR CLARITY FIGURE 2 TOP EDGE OF FIREPLA OP EDGE OF FIREPLACE CE COMB COMBUSTIBLE MANTEL USTIBLE MANTEL USE ONL USE ONLY Y NON COMB NON COMBUSTIBLE USTIBLE MA MATERIALS BELO TERIALS BELOW W TOP OF SP OP OF SPACERS CERS COMB COMBUSTIBLE...

Страница 7: ...L 4 8 L 4 8 L 1 8 L 1 8 L 3 6 L 3 6 39 5 16 76 11 16 L SERIES CHIMNEY SECTIONS L SERIES CHIMNEY SECTIONS 47 5 8 47 L48 35 5 8 35 17 5 8 17 11 5 8 11 L18 L36 L12 L18 L18 34 5 8 34 LINEAR GAIN L18 L36 52 LINEAR GAIN 52 5 8 L36 L36 70 5 8 70 LINEAR GAIN 13 O D OUTER PIPE 11 I D FLUE 4 1 2 4 1 2 34 53 1 8 44 26 3 8 15 5 8 9 3 4 9 16 OUTSIDE AIR OPENING GAS LINE OPENING 8 7 8 10 3 16 15 19 32 11 3 8 1 ...

Страница 8: ...e one that is away from frequently opened doors central heat outlets or returns or other places where air movements may disturb the airflow around the fireplace Air turbulence near the fireplace may cause smoke to spill out of the fireplace opening FULL PROJECTION FULL PROJECTION FLUSH FLUSH CORNER CORNER SIDE WALL INSTALLATION SIDE WALL INSTALLATION 53 1 8 53 1 8 64 15 16 64 15 16 MIN MIN CORNER ...

Страница 9: ...kments under or near trees or above the roof of a single story wing of a two story building as shown by Figure 9 All these conditions can cause turbulence or pressure conditions that can cause poor chimney draft and smoke spillage from the fireplace opening Elbows may be used to offset the chimney to avoid obstructions or to locate the chimney cap in a preferred location Refer to the sections of t...

Страница 10: ...FS 2 2 AIR SPACE CLEARANCE TO CLEARANCE TO COMBUSTIBLES COMBUSTIBLES 17 SQUARE 17 SQUARE OPENING IN OPENING IN JOIST JOIST 17 SQUARE 17 SQUARE OPENING IN OPENING IN JOIST JOIST 612 OR 1212 612 OR 1212 FLUE OUTLET HEIGHT FLUE OUTLET HEIGHT 2 CLEARANCE TO 2 CLEARANCE TO COMBUSTIBLES MIN COMBUSTIBLES MIN 3 FT MIN 3 FT MIN HEIGHT 86 FT CHIMNEY HEIGHT 86 FT CHIMNEY MAX INSTALLATION MAX INSTALLATION SEC...

Страница 11: ...ORM HEARTH HEARTH SB5400SS SB5400SS FIREPLACE FIREPLACE ALTERNATE BRICK OR STONE ALTERNATE BRICK OR STONE HEARTH EXTENSIONS FOR USE HEARTH EXTENSIONS FOR USE WITH THE SB5400SS FIREPLACE WITH THE SB5400SS FIREPLACE WHEN PLACED OVER A COM WHEN PLACED OVER A COM BUSTIBLE FLOOR WITHOUT BUSTIBLE FLOOR WITHOUT INSULATION BOARD PROTECTION INSULATION BOARD PROTECTION FIREPLACE AND HEARTH EXTENSION AND TOP...

Страница 12: ...to another is as follows C K divided by the material thickness Example C 43 divided by 1 2 50 C 86 K C multiplies by the material thickness Example K 86 multiplied by 1 2 50 K 43 R The material thickness divided by K Example R 1 2 50 divided by 43 R 1 16 With either type hearth extension minor shifting of the supporting floor or expansion and contraction may eventually cause a crack to develop bet...

Страница 13: ...vel 17 inch firestop spacer One required at each ceiling or floor level 6 12 12 12 pitch flashing for contemporary installation 6 12 12 12 pitch flashing for contemporary installation 0 6 12 pitch flashing for contemporary installation 0 6 12 pitch flashing for contemporary installation Round telescoping chimney cap For use with flat chase top terminations Round telescoping chimney cap For use wit...

Страница 14: ...e fireplace and chimney CHIMNEY INSTALLATION In order to assure safe and satisfactory performance of the fireplace it is very important to properly install the chimney This is an important part of the installation and the sections of this manual pertaining to chimney installation should be reviewed very thoroughly For your safety some of the important things to remember in regard to chimneys are l...

Страница 15: ...t least six inches above the roof opening on all sided As the chimney sections are installed check each joint to make sure it is properly locked to the previous section If additional strength of the outer pipe joints is desired you may use two or three sheet metal screws placed through the area where the outer pipes overlap one another To install these screws drill a 1 8 inch diameter hole through...

Страница 16: ... 1 12 2 12 3 12 4 12 5 12 6 12 7 12 8 12 9 12 10 12 11 12 12 12 INSTALLATION OF FIRESTOP SPACER AT FLOOR LEVELS INSTALLATION OF FIRESTOP SPACER AT FLOOR LEVELS INSTALLATION OF FIRESTOP SPACER AT ATTIC LEVEL INSTALLATION OF FIRESTOP SPACER AT ATTIC LEVEL FLUE PIPE FLUE PIPE FIRESTOP SPACER FLOOR JOIST HEADER CHIMNEY SECTION INLET AIR PIPE FIRESTOP SPACER CHIMNEY SECTION CEILING JOIST INLET AIR PIPE...

Страница 17: ... to the chimney at the extremities of the offset It is recommended that enclosing material not follow the inclined portions of the chimney OFFSET INSTALLATION SEQUENCE 1 Determine the location and amount of offset required then select the combinations of chimney sections and elbows required from the offset chart Refer to Page 19 2 Install the first LE30 elbow by placing the extended flue into the ...

Страница 18: ...IMNEY CAP OR CHIMNEY HOUSING CHIMNEY HOUSING FIRESTOP SPACER FIRESTOP SPACER DIAGONAL DIAGONAL CHIMNEY CHIMNEY ENCLOSURE ENCLOSURE RISE RISE C L FIRESTOP FIRESTOP SPACER SPACER 2 AIR SPACE 2 AIR SPACE CLEARANCE TO CLEARANCE TO COMBUSTIBLES COMBUSTIBLES SUPPORT STRAPS SUPPORT STRAPS DIAGONAL CHIMNEY DIAGONAL CHIMNEY ENCLOSURE ENCLOSURE OFFSET MAX 10 OFFSET MAX 10 DIAGONAL CHIMNEY ENCLOSURE DIAGONAL...

Страница 19: ...the flashing over the chimney Adjust the chimney to assure that the proper minimum clearances are maintained 5 Nail the flashing securely in place with eight nails 6 Seal the crack between the top of the flashing and the chimney with mastic Leave some excess mastic at this area to be used in step eight NOTE Use pliers and wear gloves when performing step seven to minimize the danger of cutting you...

Страница 20: ... SET 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 INTERMEDIATE INTERMEDIATE SECTIONS SECTIONS 4 0 0 1 0 1 1 0 1 1 0 2 1 0 2 1 0 2 1 3 2 1 3 2 1 3 2 4 3 2 4 3 2 4 3 5 4 3 5 4 3 5 4 6 5 4 6 5 4 6 5 7 6 5 7 6 5 7 6 8 3 1 0 0 1 0 0 2 0 1 2 0 1 3 0 2 3 1 2 0 1 3 0 2 3 1 2 0 1 3 0 2 3 1 2 0...

Страница 21: ...f flue pipe and lower it down until the 3 cap legs rest on the top edge of the outer telescope pipe Secure legs of cap to the telescope with screws provided 7 Check all parts of the chimney and chimney cap to assure that no parts have been damaged or bent during installation and that all parts have been installed properly NOTE The metal used for the chimney and chimney cap has a rust protective co...

Страница 22: ...TARTING COLLAR TO LEFT SIDE OF FIREPLACE WITH FOUR SHEET METAL SCREWS PROVIDED NOTE THE STARTING COLLAR EXTENDS THROUGH THE OUTER FIREPLACE JACKET AND WILL SEAL AGAINST THE FIREBOX WALL WHEN SECURED AS INDICATED SECURING OUTSIDE AIR STARTING COLLAR TO FIREPLACE STEP 2 SECURE OUTSIDE DUCT TO STARTING COLLAR WITH DUCT CLAMP OR SCREWS AK4 COMBUSTION AK4 COMBUSTION AIR KIT SHORTEST AIR KIT SHORTEST TO...

Страница 23: ...The assembly should be located above the snow line to prevent blockage by snow accumulation 3 The combustion air inlet assembly should never be mounted in a garage or storage area where combustible fumes such as gasoline might be drawn into the fireplace 4 Combustion air can be drawn form the crawl space under a house when an adequate supply of air is provided by open ventilation 5 Do not take com...

Страница 24: ... of the wall to which the AK 4 inlet air vent will be attached The duct may be cut with a standard pocket knife use FP 4 U duct for maximum efficiency and safety Do not use a combustible duct Always use UL Listed Class 0 or 1 duct material 5 If the duct is the insulated type push the insulation back from one end of the duct approximately two inches 6 Slip the exposed end of the duct over the start...

Страница 25: ...21 11 2 unvented room heater is installed in this fireplace a H2853 CANOPY must also be installed WARNING Do not operate an unvented gas log set in this fireplace with the chimney removed The installer of the fireplace and gas appliance must describe the operation of the fireplace and appliance to the people who will be operating them and leave all instruction manuals with the operator of the appl...

Страница 26: ... the fireplace face Seal the face of the fireplace to the surrounding wall with non combustible caulk or trim materials to prevent cold air leakage around the fireplace The trim should not block or restrict in any way the flow of air into the side air inlets in the face of the fireplace Be sure to provide the required floor protection as described in a preceding section of this manual Combustible ...

Страница 27: ...TIBLE USTIBLE MA MATERIALS BELO TERIALS BELOW W TOP OF SP OP OF SPACERS CERS COMB COMBUSTIBLE FRAMING USTIBLE FRAMING MEMBERS MEMBERS TO O TOP OF SP OP OF SPACERS CERS 12 12 MAX MAX 18 MIN 18 MIN FR FROM FIREPLA OM FIREPLACE OPENING CE OPENING TO BOTTOM OF COMBUSTIBLE MANTEL TO BOTTOM OF COMBUSTIBLE MANTEL MANUF MANUFACTURER RECOMMEND CTURER RECOMMENDATION TION TOP EDGE OF OP EDGE OF FIREPLA FIREP...

Страница 28: ...t a little combined with other wood goes a long way Start your fire with a mixture of softwood and hardwood then add some fruit or nut wood for nostalgic aroma Since most woods will not burn well when freshly cut the wood you purchase should be reasonably dry The sizes you buy are dictated by the size of your fireplace Purchase logs that will fit when laid across your grate and ask that the larger...

Страница 29: ...ss doors close them DO NOT LEAVE CHILDREN OR PHYSICALLY OR MENTALLY HANDICAPPED OR SENILE PERSONS ALONE WITH A BURNING FIREPLACE You ll need a minimum of three logs preferably four to make a good fire Add kindling and new logs as needed to rekindle a dying fire New logs should be added at the rear grate after raking the coals toward the front DO NOT OVERFIRE THE FIREPLACE Overfire conditions may b...

Страница 30: ...reosote buildup has occurred If creosote has accumulated it should be removed to reduce the risk of a chimney fire The chimney cap can be removed for inspection maintenance and cleaning by removing three screws from the support legs and lifting upward When the fireplace is first in use inspect the chimney frequently and clean the chimney any time an accumulation is observed on the flue walls The f...

Страница 31: ...of the fireplace 4 Do insulate the exterior walls surrounding the fireplace to prevent excessive heat loss from the fireplace 5 Do trim the face of the fireplace only with noncombustible materials 6 Do attach the noncombustible face trim material firmly to the face of the fireplace 7 Do block in or fasten the fireplace to prevent the possibility of the fireplace shifting out of position 8 Do enclo...

Страница 32: ...articles near the fireplace 15 Don t store or place flammable liquids gases or pressurized containers near the fireplace 16 Don t neglect to instruct all responsible persons in the proper and safe operation of the fireplace 17 Don t fail to instruct all persons especially children and elderly persons concerning the hazards of improper operation and unauthorized tampering with the fireplace 18 Don ...

Страница 33: ...E PAINTED ASSEMBLY WELDMENT DAMPER WEIGHT WELDMENT DAMPER WEIGHT HANDLE DAMPER HANDLE DAMPER FIREBRICK BACK ASSEMBLY FIREBRICK BACK ASSEMBLY FIREBRICK RT SIDE ASSEMBLY FIREBRICK RT SIDE ASSEMBLY HEARTH REFRACTORY HEARTH REFRACTORY KEY KEY NO NO 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 FIGURE 28 53D9038 Rev 1 03 03 All repair part orders should be placed through your local dealer To ensure prompt ...

Страница 34: ...mponents Cracks in ceramic and castable parts that do not affect safe operation We do not warrant this fireplace to be in compliance with your local building code Building codes vary greatly throughout the country and you should determine whether your local building code contains restrictions on the use of this fireplace before you purchase it Blowers or fans which are warranted separately Heat lo...

Страница 35: ... 1 Contact the nearest dealer If you cannot locate your dealer call or write Monessen Hearth Systems as indicated below 2 If you do not receive satisfactory service from the dealer within a reasonable time write Monessen Hearth Systems and include the date you purchased your fireplace or component its serial number and details of the problem you are having Technical Service Department 2813 W Mall ...

Страница 36: ...ATTENTION APPLIANCE INSTALLER PLEASE RETURN THESE OPERATING AND INSTALLATION INSTRUCTIONS TO THE APPLIANCE FOR CONSUMER USE 53D9038 REV 1 03 03 ...

Отзывы: