HBDV7 Series Direct Vent Gas Fireplace
54D8000
5
FP2579
HBDV7 controls
PRoDuCt FeAtuReS and GAS SPeCIFICAtIoNS
PRoDuCt SPeCIFICAtIoNS
•
This appliance has been certified for use with either
natural or propane gas. Refer to appropriate data
plates.
•
This appliance is not for use with solid fuels.
•
The appliance is approved for bedroom or bedsitting
room installations.
•
The appliance must be installed in accordance with local
codes if any. If none exist use the current installation
code. ANSI Z3.1/NFPA 54 in the USA, CSA B149 in
Canada.
•
This appliance is mobile home approved.
•
The appliance must be properly connected to a venting
system.
•
The appliance is not approved for closet or recessed
installations.
Hi/Lo Knob
Off/Pilot/On Knob
On/Off/RS Switch
Ignitor
Blower Control
Optional Remote
Receiver
FP580
Figure 1
-
HBDV300/400 Fireplace
HIGH eleVAtIoNS
Input ratings are shown in BTU per hour and are certified
without deration for elevations up to 4,500 feet (1,370
m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installation must be in accordance with the current
ANSI Z3.1/NFPA 54 and/or local codes having juris-
diction.
In Canada, please consult provincial and/or local
authorities having jurisdiction for installation at eleva-
tions above 4,500 feet (1,370 m).
GAS PReSSuReS
GAS SPeCIFICAtIoNS & oRIFICe SIZe
Max.Input Min. Input
Orifice
Model
Fuel
BTU/h
BTU/h
Size
HBDV300NV7
Nat.
3,000
16,000
.35 mm
HBDV400NV7
Nat.
7,000
19,000
#41
HBDV300NSC7 Nat.
3,000
16,000
.35 mm
HBDV400NSC7 Nat.
7,000
19,000
#41
HBDV300PV7
LP
3,000
18,000
1.50 mm
HBDV400PV7
LP
6,000
0,000
1/16
HBDV300PSC7
LP
3,000
18,000
1.50 mm
HBDV400PSC7 LP
6,000
0,000
1/16
BeFoRe you StARt
Read this homeowner manual thoroughly and follow all
instructions carefully. Inspect all contents for shipping
damage and immediately inform your dealer if any damage
is found. Do not install any unit with damaged, incomplete,
or substitute parts. Check your packing list to verify that
all listed parts have been received. You should have the
following:
•
Fireplace (Firebox and Burner System)
•
Rock Wool
•
Log Set
IteMS RequIReD FoR INStAllAtIoN
•
Phillips Screwdriver
•
Framing Materials
•
Hammer
•
Wall Finishing Materials
•
Saw and/or saber saw
•
Level
•
Electric Drill and Bits
•
Tee Joint
•
Pliers
•
Measuring Tape
•
Square
•
Pipe Wrench
•
Caulking Material (Noncombustible)
•
Fireplace Surround Material (Noncombustible)
•
Piping Complying with Local Codes
•
Pipe Sealant Approved for use with Propane/LPG
(Resistant to Sulfur Compounds)
Natural
Propane (LP)
Inlet Minimum
4.5” w.c.
11.0” w.c.
Inlet Maximum
10.5” w.c.
13.0” w.c.
Manifold Pressure
3.5” w.c.
10.0” w.c.