HBDV7 Series Direct Vent Gas Fireplace
54D8000
11
VeNtING INStAllAtIoN INFoRMAtIoN
INStAllAtIoN PReCAutIoNS
Consult local building codes before beginning the
installation. The installer must make sure to select the
proper vent system for installation. Before installing vent
kit, the installer must read this fireplace manual and vent
kit instructions.
Only a qualified installer/service person should install vent-
ing system. The installer must follow these safety rules:
•
Wear gloves and safety glasses for protection.
•
Use extreme caution when using ladders or when on
rooftops.
•
Be aware of electrical wiring locations in walls and
ceilings.
The following actions will void the warranty on your vent-
ing system:
•
Installation of any damaged venting component.
•
Unauthorized modification of the venting system.
•
Installation of any component part not manufactured
or approved by MHSC.
•
Installation other than permitted by these instruc-
tions.
W
ARNING
Read all instructions completely and thoroughly before attempting installation. Failure
to do so could result in serious injury, property damage or loss of life. operation of
improperly installed and maintained venting system could result in serious injury,
property damage or loss of life.
N
ot
IC
e
Failure to follow these instructions will
void the warranty.
this fireplace must be vented to the
outside. the venting system must NeVeR
be attached to a chimney serving a separate
solid fuel burning appliance. each gas
appliance must use a separate vent system.
Do not use common vent systems.
W
ARNING
GeNeRAl VeNtING
Your fireplace is approved to be vented either through the
side wall, or vertical through the roof.
•
only MHSC venting components specifically ap-
proved and labelled for this fireplace may be used.
•
Flexible UL1777 listed venting may be used in any vent-
ing application where rigid direct vent components can
be used. All restrictions, clearances and allowances that
pertain to the rigid piping apply to the flexible venting.
Flex kits may not be modified. Flex kits may be added to
the end of a vent run made of rigid vent sections using
pipe manufacturer's approved flex to pipe adapters. This
may occur only if doing so does not violate any of the
venting length, height, routing, horizontal to vertical raito
requirements or clearance considerations detailed in this
manual.
•
Venting terminals shall not be recessed into a wall or sid-
ing.
•
Select the amount of vertical rise desired. All horizontal
run of venting must have 1/4" rise for every 1" of run to-
wards the termination below 7
1
/
feet of vertical rise. With
7
1
/
feet or more vertical rise off top of fireplace, the hori-
zontal run may run level. NEVER run vent piping down-
ward.
•
Horizontal venting which incorporates the twist lock pipe
must be installed on a level plane without an inclining or
declining slope.
•
Horizontal venting which incorporates the use of flex
venting shall have an inclining slope from the unit of 1”
(5 mm) per 4” (610 mm).
There must not be any obstruction such as bushes, gar-
den sheds, fences, decks or utility buildings within 4”
(610 mm) from the front of the termination hood.
Do not locate termination hood where excessive snow or
ice build up may occur. Be sure to check vent termina-
tion area after snow falls, and clear to prevent accidental
blockage of venting system. When using snow blowers,
make sure snow is not directed towards vent termination
area.
location of Vent termination
It is imperative the vent termination be located observing
the minimum clearances as shown on following page.
Always maintain minimum clearances around
vent systems. the minimum clearances to
combustibles for horizontal vent pipe are 3"
at the top* and 1" at the sides and bottom
of the vent system until the pipe penetrates
the nearest vertical wall (1" required). A 1"
minimum clearance all around the pipe must
be maintained at outside wall and on vertical
runs. Do not pack the open air spaces with
insulation or other materials. this could
cause high temperatures and may present
a fire hazard.
* unless the vertical run is 7
Z\x
feet or higher
(top vent units only), the clearances for the
horizontal run is 1" at the top.
W
ARNING