6
33D0237
NATURAL GAS
Manual Pressure/T-Stat
Milli-Volt Pressure
Regulator Pressure Setting:
3 in. w.c.
Regulator Pressure Setting:
3.5 in. w.c.
Gas Inlet Pressure:
Max. 10.5 in. w.c.
Pilot Regulator:
3.5 in. w.c.
Min. 5 in. w.c.
Gas Inlet Pressure:
Max. 10.5 in. w. c.
Min. 5 in. w.c.
PRODUCT FEATURES and SPECIFICATIONS
Propane / LPG
Note: An external regulator is required to reduce supply pressure to a maximum of 13" w. c.
Manual Pressure
Milli-Volt Pressure
Regulator Pressure Setting:
10 in. w.c.
Regulator Pressure Setting:
10 in. w.c.
Gas Inlet Pressure:
Maximum 13 in. w.c.
Gas Inlet Pressure:
Maximum 13 in." w.c.
Minimum 11 in. w.c.
Minimum 11 in. w.c.
Gas Rate
Number
Model Number
Type
Max BTU/Hr
Min BTU/Hr
of Burners
DFX24NM
Manual
22,000
11,000
2
DFX24NT
T-stat
22,000
17,000
2
DFX24NV
Milli-Volt
22,000
17,000
2
DBX24NT
T-stat
10,000
N/A
1
DFX32NM
Manual
26,000
15,000
2
DFX32NT
T-stat
26,000
20,000
2
DFX32NV
Milli-Volt
26,000
20,000
2
IGNITION CONTROLS
Piezo ignitor allows ignition of the pilot without the use of matches or batteries.
Manual control has four (4) positions:
OFF
-
All gas to the gas logs is shut off at the valve.
IGN
-
Valve position to light/maintain a standing pilot.
LOW
-
Minimum gas rate — front burner provides a realistic glow on the center log.
HI
-
Maximum gas rate — front burner provides a realistic glow on the center log, plus the rear burner
provides a pleasing yellow flame.
Gas Rate
Number
Model Number
Type
Max BTU/Hr
Min BTU/Hr
of Burners
DFX24PM
Manual
22,000
11,000
2
DFX24PT
T-stat
22,000
17,000
2
DFX24PV
Milli-Volt
22,000
17,000
2
DBX24PT
T-stat
10,000
N/A
1
DFX32PM
Manual
26,000
15,000
2
DFX32PT
T-stat
26,000
20,000
2
DFX32PV
Milli-Volt
26,000
20,000
2