GAS LINE AND ELECTRICAL 
 
Gas Line Installation: 

 

NOTE 

Plumbing connections should only be performed by a qualified, licensed plumber. Main gas supply must be 

off when plumbing gas line to fireplace or performing service. 

 

 

Consult all codes. All gas piping must be installed to comply with local codes, or in the absence of local codes, 
with the latest edition of the 

National Fuel Gas Code ANSI Z223.1 

 

The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during 
any pressure testing of that system at test pressure in excess of 1/2 psi (3.5 kPa).   

 

The appliance must be isolated from the gas supply piping system by closing the equipment shutoff valve 
during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.5 
kPa).   

 

Use new black iron or steel pipe. Internally tinned copper or copper tubing can be used per 

National Fuel Gas 

Code, section 2.6.3

, providing gas meets sulfide limits, and where permitted by local codes. 

 

 

An ANSI approved manual shutoff valve must be installed immediately upstream of the gas supply connection 
to the fireplace 

 

A sediment trap may be installed upstream of the fireplace to prevent moisture and contaminants from passing 
through to the fireplace control and burner. Failure to do so could prevent appliance from operating reliably.

 

 

On some local codes, the gas line must be connected to a gas shut-off valve recessed  flush into the wall or floor 
outside the fireplace. The valve should be controlled by a removable valve key for safety.

  

In this case, remove 

factory shut-off valve from the flex line and connect line direct to stub. 

 

WARNING 

Support the shut-off valve when attaching 1/2” gas line. Use a wrench to hold shut-off valve stationary.       

Do not twist the flex line when tightening the 1/2” gas line.

 

 

WARNING 

Connecting directly to an unregulated propane/L.P.G. tank can cause an explosion.   An external regulator 

must be used on all propane/LPG appliances to reduce the supply tank pressure to 13” w.c. (maximum). 

 

WARNING 

Do not connect directly to natural gas 1/2- psi or 2-psi systems.  Always make sure the natural gas pressure is 

regulated to 10.5 w.c.  (maximum) before operating the unit. 

 

 

Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is 
different from the fireplace, 

STOP! Do not install the appliance.

  Contact your dealer immediately. 

 

To ease installation, a 30” flex line with manual shut-off valve has been installed on this fireplace. Install 1/2” 
gas line onto shut-off valve.  

 

Locate the gas line access hole in the outer casing of the fireplace.  Remove the screw on the gas line cover 
plate.  Open the fireplace door, insert the gas supply line through the knock out hole on the gas line cover plate, 
and connect it to the shut-off valve. 

 

After completing gas line connection, purge air from gas line and test all gas joints from the gas meter to the 
fireplace for leaks. Use a soap and water solution or a gas sniffer.  

 

To check gas pressure at valve, turn captured screw counter clockwise 2 or 3 turns and then place tubing to 
pressure gauge over test point. Refer to Figure 12: Gas Pressure Check at Gas Valve. After taking pressure 
reading, be sure and turn captured screw clockwise firmly to re-seal. Do not over torque. Check for gas leaks. 

 

WARNING 

Do not use open flame to check for gas leaks. 

 

15 

Содержание 724BV4536NE

Страница 1: ...TO HIGH TEMPERATURES THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURE AND SHOULD S...

Страница 2: ...NG VENT COMPONENTS 11 BEFORE YOU START 11 PIPING INSTALLATIONS 11 VENT TERMINATION 13 OUTSIDE AIR KIT INSTALLATION 14 GAS LINE AND ELECTRICAL 15 GAS LINE INSTALLATION 15 ELECTRICAL WIRING 16 FINAL INS...

Страница 3: ...xternal vent cap on a regular basis to make sure that no debris is interfering with the airflow Provide adequate clearances around air openings and adequate accessibility clearance for servicing and o...

Страница 4: ...ltitudes up to 2000 ft When installing this fireplace at an elevation above 2000 ft it may be necessary to decrease the input rating by changing the existing burner orifice to a smaller size Input sho...

Страница 5: ...ation of your appliance This includes determining where the unit is to be installed the vent configuration to be used framing and finishing details and whether any optional accessories i e wall switch...

Страница 6: ...P PR RE E I IN NS ST TA AL LL LA AT TI IO ON N I IN NF FO OR RM MA AT TI IO ON N Figure 1 Fireplace Dimensions 5...

Страница 7: ...T TI IO ON N I IN NF FO OR RM MA AT TI IO ON N Figure 2 Fireplace Locations and Minimum Clearances Requirements CAUTION Measure fireplace dimensions and verify framing methods wall covering details be...

Страница 8: ...bottom of the appliance Refer to Figure 3 Back wall Clearance The appliance may be placed against a combustible back wall NOTE There are 1 4 ribs spacers on the outer shell of the unit to maintain mi...

Страница 9: ...hard combustible surface i e flat wood plywood or particleboard Be sure that the fireplace rests on a solid continuous floor or platform with appropriate framing support Do NOT install appliance direc...

Страница 10: ...le materials i e brick tile slate steel or other materials with a UL fire rating of Zero may be used to cover the black surface of the appliance A 300 F minimum adhesive may be used to attach facing m...

Страница 11: ...tion and frame later Be sure fireplace is resting on a flat surface 3 Set unit level and plumb by checking the top and front of unit Shim side to side and front to back as necessary 4 Anchor nailing f...

Страница 12: ...the manual with the termination cap thoroughly before installing unit or vent system After vent configuration has been decided begin attaching pipe to unit Piping Installations 1 Attached the first pi...

Страница 13: ...om the pipe manufacturer To Locate and Install Ceiling Firestop For ceiling firestops position a plumb bob over the center of the vertical pipe to spot a hole through which the pipe will penetrate Dri...

Страница 14: ...r building codes specify a minimum vent height above the rooftop depending on the pitch of the roof Refer to the above figure for minimum heights provided the termination cap is at least eight 8 feet...

Страница 15: ...en it meets the roof Attach a storm collar over the flashing joint to form a watertight seal Place non hardening mastic around the joint between the storm collar and the vertical pipe Attach terminati...

Страница 16: ...le valve key for safety In this case remove factory shut off valve from the flex line and connect line direct to stub WARNING Support the shut off valve when attaching 1 2 gas line Use a wrench to hol...

Страница 17: ...ectrical Code ANSI NFPA 70 latest edition or the Canadian Electrical Code CSA C22 1 Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operat...

Страница 18: ...ol Refer to Figure 13 Wiring Diagram for Standing Pilot Millivolt System The millivolt system and individual components may be checked with a millivolt meter having 1 1000 mV range Conduct each check...

Страница 19: ...main burner does not come on then replace control valve 9 If meter is reading less than 175 millivolt then refer to TROUBLESHOOTING section of this manual to determine the cause of the low reading El...

Страница 20: ...due to high temperatures inside the chamber This will prevent failures and longer battery life 1 Plug in the remote connector wire to the remote receiver 2 Connect the wire terminal from the remote re...

Страница 21: ...top edge of the fireplace but must never overlap the black metal face The black metal face may be covered with non combustible material only After applying the finishing material a non combustible sea...

Страница 22: ...in bottom of log with grate bar Step 3 Place Front Right Log 3 on right front of grate bar lining up cutout in bottom of log with grate bar Make sure Log 3 touches Log 1 Step 4 Place back end Top Mid...

Страница 23: ...ned or completely closed 1 Remove and discard the two 2 screws that secure the C Channel below the top opening of the fireplace 2 Attach bottom rail 1 to unit with 2 sheet metal screws 3 Refer to Figu...

Страница 24: ...igure 22 WARNING Damper must be in open position when appliance main burner is operating The damper system must be LOCKED into the OPEN position during operation If damper is not open the appliance wi...

Страница 25: ...every second Subsequent lighting of the fireplace will not require this purging of air from the gas lines unless the gas valve has been shut off for a long period Lighting the Fireplace You may notice...

Страница 26: ...next step 6 Find Pilot located under the log 7 Turn gas valve counterclockwise to Pilot 1 Open left side access door 2 Turn RS OFF ON rocker switch to OFF 3 Push in gas valve knob slightly and turn c...

Страница 27: ...burner by hand Electronic Gas Valve LIGHTING INSTRUCTIONS ELECTRONIC IGN 1 Turn RS OFF ON rocker switch to OFF 2 Turn off all electric power to the appliance if service is to be performed TO TURN OFF...

Страница 28: ...the pilot should be visually checked as soon as the heater is installed and periodically during normal operation The pilot flame must always be present when the fireplace is in operation Refer to Fig...

Страница 29: ...roken Caution Replace any glass that is chipped cracked or broken Replacement glass door assemblies MUST be supplied by the fireplace manufacturer Warning No substitute materials may be used Warning H...

Страница 30: ...Firebrick right side 1 26D7135 26D7135 2d Firebrick center 42 1 26D7138 3 Pull Screen 1 MS MS 4 Bi Fold Brass Black Doors 1 BBD4536 BLD4536 BBD5142 BLD5142 5 Manual Remote Control 1 RCM RCB RCM RCB 6...

Страница 31: ...lve 1 23D6046 23D6046 23D6046 23D6046 5 Rocker Switch 1 41D0048 41D0048 41D0048 41D0048 6 Piezo Igniter 1 14D0503 14D0503 14D0503 14D0503 7 Injector 1 32D0100 32D0118 32D0100 32D0118 8 Burner Assembly...

Страница 32: ...cker Switch 1 41D0048 41D0048 41D0048 41D0048 7 Injector 1 32D0100 32D0118 32D0100 32D0118 8 Burner Assembly 1 41D0500K 41D0501K 41D0500K 41D0501K 9 Wire Assembly 1 54D2007 54D2007 54D2007 54D2007 14...

Страница 33: ...nection Place jumper wires across terminals of switch If burner comes on replace defective switch If the switch is OK repeat the same procedure on remote control If burner comes on replace remote cont...

Страница 34: ...ELECTRONIC IGNITION 33...

Страница 35: ...ed by a decorative enclosure Remove or open enclosure or raise cap above it B Cap is crushed damaged or missing Replace cap 4 Poor draft due to ext environment A Buildings trees roof lines interfering...

Страница 36: ...ve finished grade in the area of the venting including but not limited to decks and porches the following requirements shall be satisfied 1 INSTALLATION OF CARBON MONOXIDE DETECTORS At the time of ins...

Страница 37: ...d in whole or in part for residential purposes c MANUFACTURER REQUIREMENTS GAS EQUIPMENT VENTING SYSTEM PROVIDED When the manu facturer of Product Approved side wall horizontally vented gas equipment...

Страница 38: ...if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 firebox burner assembly damage by accident neglect misuse...

Отзывы: