P
P
R
R
E
E
-
-
I
I
N
N
S
S
T
T
A
A
L
L
L
L
A
A
T
T
I
I
O
O
N
N
I
I
N
N
F
F
O
O
R
R
M
M
A
A
T
T
I
I
O
O
N
N
CAUTION
Measure fireplace dimensions and verify framing methods & wall covering details before framing
construction begins.
Finishing Material:
NOTE
Any remote wiring (i.e. remote control, wall switch or 120 volt wiring) must be done prior to final finishing to
avoid costly reconstruction.
Only noncombustible materials (i.e. brick, tile, slate, steel, or other materials with a UL fire rating of Zero) may be
used to cover the black surface of the appliance. A 300
°
F minimum adhesive may be used to attach facing materials
to the black surface. If joints between the finished wall and the fireplace surround are sealed, a 300
°
F minimum
sealant material (General Electric RTV103 or equivalent) must be used. Refer to Figure 7.
Combustible
Material
High temperature sealant
permitted at these joints
Noncombustible materials only
are permitted to cover black face
of unit
Figure 5: Finishing Material
9
Содержание 724BV4536NE
Страница 34: ...ELECTRONIC IGNITION 33...