Technical service manual
11
UK
have a RS232 port use the USB/RS232 adapter code 8-21100226.
- Turn the wheel balancer on.
- Open the previously downloaded file with the .”bin” extension of the firmware
version to be updated. The control window for the SAB16X programme will open
automatically.
- Select the COM serial port where the programming cable is connected to the PC.
- Select the Start
key to start the programming.
- The programme starts by deleting the software version on the card to be updated,
displaying the following image on the status bar.
- When the “Programming” box opens, the “OK 100%” message means that the pro-
gramming was completed successfully.
- At the end of programming, close the programme, turn off the machine and return the
deep switch to its original position (all switches are OFF).
- If an error message is displayed, check the serial cable wiring harness and repeat the
programming procedure, turning the machine off and then on.