background image

7

NOTE:

There are maximum and minimum values in each mode
beyond which you cannot adjust.  If you are adjusting the
rate and you reach a value which on the next increment would
exceed the maximum flash rate, the display will not increment.
The same is true if you try to adjust the flash rate below the
minimum flash rate.

To multiply or divide the current flash rate by 2:

In addition to the knob, there are two buttons on the back panel
marked 

x2

 and 

÷2

.  This enables the user to instantly double or halve

the reading on the display to the maximum or minimum values allowed.
This feature is useful for checking harmonics in the internal flashing
mode.

Alternate Knob Function (multiple by 2, 3, 4, 5, etc.)

The tuning knob functions differently when 

ALT.

 

is displayed. The

current flash rate is used as an adder.  The knob will add (counter
clockwise) or subtract (clockwise) that initial flash rate for each “click”
the knob is turned. This in effect allows the user to multiply the initial
flash rate by 2, 3, 4, 5, etc up to the maximum flash rate. This is very
helpful on fan blades.  Using this feature, one can superimpose the
blades on top of each other and check for blade tracking, bent blades,
lead and lag tests, etc.

For example: A 3 bladed fan is spinning at 3600 RPM. The strobe is
flashing at 3600 FPM. Press the 

ALT FUNCTION

 

button to display

ALT

. Then turn the knob counter clockwise 2 clicks. The strobe will

now flash at 10,800 FPM (effectively 3600 times 3).  The fans blades
will be all superimposed on each other. One can now see if the blades
are out of alignment, bent, etc. by viewing the blades from the front or
viewing from the side edge of the blades.

14

while pushing it into place (see Figure 4). Make sure the lamp is
in straight and centered in the reflector hole.

CAUTION:

Do NOT allow the reflector to contact the lamp.

4.

Reinstall the reflector and then position the front lens in place
matching up the notches on the lens with the two small tabs on
the housing to prevent lens rotation (see Figure 4). Push the tabs
on the front rim outward and press the lens into place.

Figure 4  Lamp Replacement

Red Dots

Notches

Содержание Nova-Strobe DBX

Страница 1: ...ENT Instruction Manual 15 Columbia Drive Amherst NH 03031 USA Phone 603 883 3390 Fax 603 886 3300 E mail support monarchinstrument com Website www monarchinstrument com Nova Strobe dbx shown Printed i...

Страница 2: ...nt or severe personal injury or death may occur as a result 8 This instrument may not be safe for use in certain hazardous environments and serious personal injury or death could occur as a result of...

Страница 3: ...narch Instrument s Limited Warranty applies See www monarchinstrument com for details Warranty Registration and Extended Warranty coverage available online at www monarchinstrument com CE DECLARATION...

Страница 4: ...al and sensor power CA 4044 6 6 foot 1 8 m Input Output cable 1 8 inch 3 5 mm male phone plug to male BNC connector CA 4045 6 6 foot 1 8 m Input Output cable 1 8 inch 3 5 mm male phone plug to 1 8 inc...

Страница 5: ...cy exceeds the limit of the stroboscope Battery Powered Model Only Battery indication see section 7 0 Figure 1 Display Panel 20 dbx Specific Trigger to Flash Delay 13 sec typical Input Power Battery p...

Страница 6: ...00 nanosec min pulse width Positive or Negative edge triggered menu selectable Output Pulse 40 sec positive negative pulse menu selectable 3 3 Vdc typical Note dax Input Output connectors isolated fro...

Страница 7: ...nal Input Figure 2 Input Connector Detail Stereo plug 18 7 3 Battery Disposal Prior to disposing of the battery powered strobe the user must remove the Nickel Metal Hydride batteries To do this remove...

Страница 8: ...g if the battery voltage is too low This condition is indicated by no flash and the display shows LO BAT At this time the batteries must be recharged Remember to release the trigger switch 7 2 Chargin...

Страница 9: ...ble NiMH Nickel Metal Hydride batteries These batteries contain fewer toxic metals than NiCd Nickel Cadmium and are currently classified environmentally friendly They also have 30 more capacity than N...

Страница 10: ...hing is plugged into the input jack or when manually set using the INPUT button To change the flash rate With the power on turn the knob counter clockwise to increase the flash rate and clockwise to d...

Страница 11: ...ultiply the initial flash rate by 2 3 4 5 etc up to the maximum flash rate This is very helpful on fan blades Using this feature one can superimpose the blades on top of each other and check for blade...

Страница 12: ...the bottom line and the current flash rate will be displayed on the top line 13 6 0 LAMP AND FUSE REPLACEMENT 6 1 Lamp Replacement WARNING Before attempting to remove the lamp make sure the strobosco...

Страница 13: ...ting at 5000 RPM If the speed is outside the full scale range of the stroboscope 20 000 FPM it can be measured using the method of harmonics and multipoint calculation Start at the highest flash rate...

Страница 14: ...der to do this several factors need to be considered First the object being measured should be visible for all 360 of rotation e g The end of a shaft Second the object should have some unique part on...

Отзывы: