SPECIFICATIONS

Range:

5 to 99,999 RPM

Accuracy:

±1 RPM or 0.005% of reading

Resolution:

1 RPM

Display:

5 digit, 0.56” (14 mm) high red LED

Display Update:

Twice per second above 120 RPM

Dimensions:

1/8 DIN by 4.5” (114 mm) deep

Power Supply:

Standard: 115 Vac or 230 Vac 

±

10%, 50/60 Hz

(Specified when ordering)
Optional:  12 Vdc to 15 Vdc, 1.75 Watts

Inputs:

Universal input for optical, proximity, two wire or
three wire magnetic, infrared or laser Sensors
TTL input or 1.5 Vac to 50 Vac input
Standard inputs are 1, 10 or 60 pulses per revolution
depending on the model.  Contact factory to order
customized pulses per revolution.

Sensor Excitation:

8 Vdc at 5 mA for proximity sensors
5 Vdc at 75 mA for all other sensors

Recommended Sensors:

Optical

- Monarch ROS-5W

Proximity - Monarch P5-11
Magnetic - Monarch M-190W or MT-190W
Infrared

- Monarch IRS-5W

Laser

- Monarch RLS-5W

IO Option:

4 to 20 mA, see page 7 for maximum load calculation
Full scale RPM settings as specified when ordered
12 bit resolution, 4096 steps over the range specified

AO Option:

0 to 5 Vdc, 5 mA maximum load
Full scale RPM settings as specified when ordered
12 bit resolution, 4096 steps over the range specified

PO Option:

0 to 5 V TTL pulse, non-inverting, one pulse out for each
pulse in

ACCESSORIES / SENSORS

ROS-5W:

Remote Optical Sensor

T-5:

Reflective Tape - 5 foot (1.5 m) roll, 0.5 inch (10 mm) wide

P5-11:

Proximity Sensor

M-190W:

Magnetic Sensor

MT-190W:

Magnetic Sensor with Amplifier Module

IRS-5W:

Infrared Sensor

RLS-5W:

Laser Sensor

NOTE:

Standard cable length is 8 feet (2.5 m) on all sensors.  Longer
cable lengths of 15, 30, 50 or 100 feet ( 4.6, 9.2, 15 or 30.5 m)
are optional.

10

Содержание ACT-1B-10

Страница 1: ...TRUMENT Instruction Manual 15 Columbia Drive Amherst NH 03031 2334 USA Phone 603 883 3390 Fax 603 886 3300 E mail techsup monarchinstrument com Website www monarchinstrument com Printed in the U S A M...

Страница 2: ...all material respects when used in strict compliance with such documentation or manual Notwithstanding the foregoing BUYER acknowledges that since software is complex and therefore may have defects B...

Страница 3: ...y that the product to which this declaration relates is in conformity with the following standards and therefore conforms with the requirements of Council Directive 89 336 EEC relating to electromagne...

Страница 4: ...ed Sensors Optical Monarch ROS 5W Proximity Monarch P5 11 Magnetic Monarch M 190W or MT 190W Infrared Monarch IRS 5W Laser Monarch RLS 5W IO Option 4 to 20 mA see page 7 for maximum load calculation F...

Страница 5: ...terminal connections on the rear panel of the instrument If specified at time of order placement the ACT 1B may be equipped with either an optional 4 to 20 mA current output IO or 0 to 5 Vdc analog ou...

Страница 6: ...d N Connect the Ground Earth wire to the terminal marked GND NOTE For full compliance with CE specifications the Ground GND connection must be made Analog Output Option AO The analog output is 0 to 5...

Страница 7: ...Contact the factory for increased sensitivity Connect the signal wire from three wire sensors or the positive side of two wire magnetic sensors to this terminal Typical input impedance is 10 Kohms COM...

Страница 8: ...the rear panel CAUTION The IO or AO COM is NOT isolated from the other COM connections Current Output Option IO The current output is 4 to 20 mA This output is a current sink and requires a source vol...

Отзывы: