background image

4

I. DRAIN CONNECTION AND OVERFLOW

- 2.5mtrs of white low pressure drain hose is supplied with the 

unit. This is to be used for both the drain and overflow. The drain 

connection is the black barbed elbow on top of the valve (Pic C). Fix 

drain hose to black barbed elbow with jubilee clip (supplied).

- Run the drain hose to either an upstand or an outside drain. A 

minimum air gap of 20mm should exist at the end of the drain line 

(Fig 2.)

- If you need to extend the drain hose, this can be done by 

connecting to a 15mm copper tube for a maximum run of 4 metres, 

with a minimum daytime pressure of 40 psi. Over 4 metres please 

use 22mm copper tube.

- Ensure that the drain hose is adequately fixed to the copper pipe.

- The drain hose must not dip or be kinked in any way, as this will 

lead to an overflow of the machine.

- UPHILL? The white flexible drain hose can run uphill internally, for a 

maximum of 3 feet, with a minimum water pressure of 40 psi.

- Softened water will have no adverse effect on a septic tank.

- Under no circumstances should the softener drain and overflow 

MONARCHWATER.CO.UK

01986 784759

[email protected]

H. INLET & OUTLET CONNECTIONS

- Remove grey retaining clips and also BSP connection points. Connect 

hoses to male BSP connection points, tighten to seal, then reinsert BSP 

connection points back into valve body. Fit grey clips. The connection 

points are designed to rotate once inserted in valve body. This removes 

any stress/pressure placed upon the angle/direction of hoses when 

connecting same to Rapid-Fit bypass.

- We recommend you fit the elbow end of the hose to the inlet/outlet 

connection points on the softener.

- Using the stem elbow, insert into bulkhead on the salt tank as Pic A, 

having greased stem slightly prior to inserting.

Cut to length allowing extra for when salt tank or softener needs to be 

moved for service etc. 

Chamfer the end of the tubing (maximum 1mm) and insert into the

push-fit connector on the short piece of white 3/8” tubing as Pic B. 

IMPORTANT: Lubricate both stem on elbow and tubing end for

speedfit connection on valve prior to inserting. Insert approx 1.5cm for 

correct seal.

Under no circumstances use washing machines hoses or plumb the 

softener in solid copper pipe.

J. OVERFLOW CONNECTION - Important

- The hose for the overflow should be cut from the white low 

pressure hose supplied with the unit.

- The overflow connection is the 1/2” hose spigot on the salt tank.

- The overflow must be run downhill to drain.

SALT TANK

Overflow 

hose to 

relevent 

drain with 

20mm air 

gap

Fig 2.

Stem elbow fitted into

bulkhead on salt tank

Push fit

connection

Pic A.

Pic B.

Pic C.

Drain elbow

Содержание SOF3000 HE

Страница 1: ...INSTALLER AND USER GUIDE SOF3000 HE MONARCHWATER CO UK 01986 784759 INFO MONARCHWATER CO UK NEVER KNOWINGLY BETTERED Effective 1st September 2020 ...

Страница 2: ...tic tank and insulate well Monarch take no responsibility of any water damage etc if this recommendation is not applied The overflow on the plastic tank should be below the overflow of the softener and a minimum of 3 4 in size Failure to install the softener in a suitable tank will void the Guarantee C CHECK VALVE Domestic Ion exchange water softeners are in fluid category 2 The Rapid Fit bypass i...

Страница 3: ...D FIT BYPASS Form an installation as per Fig 1 below Water pressure 1 5 5 bar 20 70psi Access to incoming water supply Access to 3 pin socket Access to drain Installation preferably on an outside wall for the overflow Easy access to fill unit with salt Fig 1 CHECKLIST Power ...

Страница 4: ...nect hoses to male BSP connection points tighten to seal then reinsert BSP connection points back into valve body Fit grey clips The connection points are designed to rotate once inserted in valve body This removes any stress pressure placed upon the angle direction of hoses when connecting same to Rapid Fit bypass We recommend you fit the elbow end of the hose to the inlet outlet connection point...

Страница 5: ...ONTROLLER Turn on power and the softener display will say WELCOME The Display is a 2 line display Pic D showing both the Model No and also Time and Hardness The Time and Hardness will alternate every 10 seconds To finalise commissioning of the softener you need to set both time 24hr clock in hours and minutes and the water hardness as determined by the amount of drops in your water hardness test 0...

Страница 6: ...tres of water to the salt tank on initial installation only If at any time you see excess water in the salt tank please call our service department on 01986 784759 P SET WATER HARDNESS Wait until display changes to Hardness Press Up Button to show Set Hardness with no flashing Use Up Button to set number as determined by your water hardness test Press to confirm setting You have finished the progr...

Страница 7: ...een colour change as per the original water hardness test NOTE This blended water setting can only be done when the softener is in Service Blending control valve FURTHER INFORMATION Do not worry if your softener regenerates during the day This is the Self Protect Programme initiating an additional mini regeneration as the softener does not have enough soft water to last you until the next programm...

Страница 8: ... the unit and confirmed by the pics adjacent Reverse the above and place bypass back in Service upon your return Reset time if necessary by reverting to Set Time of Day Activate a manual regeneration by pressing left hand button on controller Display will countdown from 15 to zero Please be aware that during the regeneration the softener goes onto automatic hard water bypass so it is recommended t...

Страница 9: ...pply to rinse aid On dishwashers connected to hard water you should continue to put salt into the dishwasher s own softener If in any doubt if your machine should have either hard or soft water please contact your dishwasher manufacturer but remember they want to sell you spare parts to replace those that get scaled up 9 Steam Irons We do not recommend the use of soft water in your steam iron as m...

Страница 10: ...TABLET SALT ONLY 6 The use of any other hoses than those provided Under no circumstances use washing machine hoses 7 The build up of salt fines in the bottom of the salt tank Although Monarch recommends Ultimate please note it is the customers responsibility to ensure the salt is of good condition when used 8 The effect of aggressive water the degradation and or blinding of resin and or chlorine a...

Страница 11: ...arantee Once the parts exchange guarantee has expired Monarch reserves the right to make a charge for any postage delivery labour and parts charges that is deemed necessary Monarch will endeavour to keep these charges at the lowest cost whenever possible with any costs confirmed to the customer before costs are incurred MONARCHWATER CO UK 01986 784759 INFO MONARCHWATER CO UK Your Monarch HE water ...

Страница 12: ...your existing guarantee to be a full 10 year parts and labour guarantee our Platinum service simply call our main number below and select Option 2 for Service We will then forward details of all our service plans for your consideration Once again thank you for supporting Monarch Water Yours faithfully MONARCH WATER LTD Effective 1st September 2020 ...

Отзывы: