5
PLEASE NOTE
The unit is supplied with nipple connections for both inlet and outlets on the
connection head. Insert 1" fibre washers into the heads up against the shoulder at
the end of the female thread. Insert nipples up against fibre washers and tighten
against shoulder to seal.
I. TEST INSTALLATION FOR LEAKS
Close Inlet and Outlet valves to the unit and open Bypass valve.
Open mains stopcock and flush the new pipe work for a minimum of 5 minutes.
This can be done using any mains water tap inside the property i.e. utility
room, kitchen cold tap or wash hand basin in a bathroom.
Close Bypass valve, then open Inlet and Outlet valves slowly.
Allow water to run slowly until all air is purged from the unit, then close tap.
Allow unit to rest for 15 minutes before future use. Check for leaks.
FIG 2
Connect the inlet hose from the INLET valve/male iron adapter on the pipe work
to the INLET of the Scaleout - see directional arrow on top of unit.
Connect the outlet hose from the OUTLET valve/male iron adaptor on the pipe
work to the OUTLET of the Post Filter.
GOING ON HOLIDAY?
• Fig 2 shows the valves in the Service position
(Bypass is closed and Inlet & Outlet are open).
• We highly recommend you bypass your unit
when going away on holiday.
• Simply turn Inlet, Outlet and Bypass valves
¼ turn to put valves into Bypass positions.
• Upon your return, move valves back to the
Service position (as Fig 2 right).
MAINTENANCE
a. Change resin every 3 years or before if water
quality decreases.
b. Change post filter every 12 months or before
if water quality decreases.
Post Filter models
SXP15 & SXP22: SXPF5
SXP28 & SXPLC: SXPF10