3
MONARCH SCALEOUT INSTALLATION INSTRUCTIONS
Thank you for choosing our SCALEOUT XP. Please read the following carefully,
which if followed correctly, should ensure the installation is trouble free.
Before you install the unit, please ensure you have the correct model with regard
to demand placed upon unit and also the water hardness. models are
used on all water hardness over 500ppm. Monarch has a nationwide database on
all water hardness’s for your assistance
A. PLANNING THE INSTALLATION
• Always observe the water byelaws.
• Ensure there is only one rising main.
• Make sure you have allowed space for access to the unit for any possible
maintenance in the future.
• Check the water pressure and locate the rising main. Be aware of
condensation occurring in warm environments. If condensation occurs, we
recommend the unit is sited in a small tray that allows the water to evaporate.
• Unit must be kept upright.
B. SITING THE SCALEOUT
• Where possible, this should be close to the rising main.
• ‘T’ off for an untreated mains supply for the outside tap.
• Ensure that the unit is not subject to below 4 or above 50ºC.
• If siting the unit within a kitchen cupboard, loft etc. Ensure that the base/
floor is adequately supported.
• If the unit is being installed in your loft, 1st, 2nd floor etc., it is recommended
to house the unit within a plastic tank and insulate well.
• The overflow on the plastic tank should be a minimum of ¾”in size. Failure to
install the unit in a suitable tank will void the Guarantee.
C. CHECK VALVE
In domestic applications i.e. house, bungalow, apartment, flat etc, a single check
valve should be fitted. All other applications require a double check valve.
D. DRINKING WATER FACILITY
The unit produces drinking water, so unlike a salt based softener, no dedicated
tap is required.
E. MATERIAL CHECK LIST
• The unit includes an installation kit as relevant to the model ordered.