background image

3

MONARCH SCALEOUT INSTALLATION INSTRUCTIONS

Thank you for choosing our SCALEOUT XP. Please read the following carefully, 
which if followed correctly, should ensure the installation is trouble free.
Before you install the unit, please ensure you have the correct model with regard 
to demand placed upon unit and also the water hardness. models are 
used on all water hardness over 500ppm. Monarch has a nationwide database on 
all water hardness’s for your assistance

A. PLANNING THE INSTALLATION

•  Always observe the water byelaws.
•  Ensure there is only one rising main.
•  Make sure you have allowed space for access to the unit for any possible  
  maintenance in the future.
•  Check the water pressure and locate the rising main. Be aware of    

 

  condensation occurring in warm environments. If condensation occurs, we  
  recommend the unit is sited in a small tray that allows the water to evaporate.
•  Unit must be kept upright.

B. SITING THE SCALEOUT

•  Where possible, this should be close to the rising main.
•   ‘T’ off for an untreated mains supply for the outside tap.
•   Ensure that the unit is not subject to below 4 or above 50ºC.
•   If siting the unit within a kitchen cupboard, loft etc. Ensure that the base/
  floor is adequately supported.
•  If the unit is being installed in your loft, 1st, 2nd floor etc., it is recommended  
  to house the unit within a plastic tank and insulate well.
•  The overflow on the plastic tank should be a minimum of ¾”in size. Failure to  
  install the unit in a suitable tank will void the Guarantee.

C. CHECK VALVE

In domestic applications i.e. house, bungalow, apartment, flat etc, a single check 
valve should be fitted. All other applications require a double check valve.

D. DRINKING WATER FACILITY 

The unit produces drinking water, so unlike a salt based softener, no dedicated 
tap is required.

E. MATERIAL CHECK LIST

•   The unit includes an installation kit as relevant to the model ordered. 

Содержание Scaleout XP

Страница 1: ...Installer User Guide Effective June 2018 Suppliers to H M the Queen s Estate at Sandringham Monarch Water Ltd T 01986 784759 F 01986 784769 info monarchwater co uk www monarchwater co uk Model No For Monarch Scaleout ...

Страница 2: ...or some time whilst the system is de scaling This is particularly noticeable in your bath and shower 5 Dishwashers On most installations the dishwasher is to be connected to the Scaleout water We recommend that you continue to add a small amount of salt to the appliance as before as this helps the salt holder in the appliance stay clean We do not however recommend that crystal glass solid silver o...

Страница 3: ...n a small tray that allows the water to evaporate Unit must be kept upright B SITING THE SCALEOUT Where possible this should be close to the rising main T off for an untreated mains supply for the outside tap Ensure that the unit is not subject to below 4 or above 50ºC If siting the unit within a kitchen cupboard loft etc Ensure that the base floor is adequately supported If the unit is being inst...

Страница 4: ...ytime pressure can reach nearly 100psi at night Minimum dynamic pressure must exceed 1 5 bar If in any doubt please call us on 01986 784 759 4 H INLET OUTLET CONNECTIONS See Fig 1 Under no circumstances use washing machine hoses or plumb the unit in solid copper pipe Ensure nipples when used have been tightened to seal G INSTALL BYPASS VALVES CHECK VALVE Form an installation as per Fig 1 Below Che...

Страница 5: ...the unit then close tap Allow unit to rest for 15 minutes before future use Check for leaks FIG 2 Connect the inlet hose from the INLET valve male iron adapter on the pipe work to the INLET of the Scaleout see directional arrow on top of unit Connect the outlet hose from the OUTLET valve male iron adaptor on the pipe work to the OUTLET of the Post Filter GOING ON HOLIDAY Fig 2 shows the valves in ...

Страница 6: ...ypass Close both Inlet Outlet valves and open Bypass valve For Normal Service Open both Inlet Outlet valves and close the Bypass valve 4 Call outs due to incorrect installation If you have any queries when installing your Scaleout please call us on 01986 784759 5 The use of any other hoses than those provided Under no circumstances use washing machine hoses 6 The effect of aggressive water the deg...

Страница 7: ... are to be covered strictly by a parts only exchange guarantee as determined by the model range of softeners i e Plumbsoft with 7 years parts All parts sent back to Monarch are at the expense of the sending parties All repaired or replaced items will be returned to the sender on a no charge basis whilst covered by the parts exchange guarantee Once the parts exchange guarantee has expired Monarch r...

Страница 8: ..._____ ______ 20____ 4th Cartridge Change Date ______ ______ 20____ 5th Cartridge Change Date ______ ______ 20____ 6th Cartridge Change Date ______ ______ 20____ 7th Cartridge Change Date ______ ______ 20____ 8th Cartridge Change Date ______ ______ 20____ 9th Cartridge Change Date ______ ______ 20____ 10th Cartridge Change Date ______ ______ 20____ 11th Cartridge Change Date ______ ______ 20____ 12...

Отзывы: