background image

INTRODUCTION

The 

SPSR-IM

 

Self Powered Sensor Interface Module

 is a self-contained, 

rechargeable battery powered device for developing a TTL compatible one 

pulse per revolution output for triggering external equipment such as vibration 

analyzers, spectrum analyzers, stroboscopes, data acquisition equipment, 

tachometers, balancers, waveform analyzers and magnetic tape recorders.

T h e  

S P S R - 11 5 / 2 3 0

 i s 

comprised of the 

SPSR-IM

 

Interface Module

, which 

provides power to a sensor 

and couples the sensor to a 

BNC output; an input sensor 

with a visible red LED light 

source (

ROS-P

); and a battery 

recharger.

Optional sensors such as an optical 

laser sensor (

ROLS-P

-not shown), 

infrared sensor (

IRS-P

), or an 

amplified magnetic sensor (

MT-

190P

) may also be combined with the 

SPSR-IM Interface Module

 when 

appropriate. (See separate instructions for these configurations.)

FUNCTIONS AND OPERATION

SPSR Interface Module

The 

SPSR Interface Module 

(

SPSR-IM

) provides power to the input 

sensor, receives and optionally inverts the return pulse signal, and provides 

a switch selectable positive going 0 to 5 Vdc or negative going 5 to 0 Vdc 

1

MT-190P

Magnetic Trigger Sensor

IRS-P

Infrared Sensor

2

pulse train trigger output on a BNC connector.  Connections and operation 

are common to all SPSR models.  Fully charged internal NiMH batteries will 

typically provide greater than 40 hours of continuous operation.  In addition, 

the SPSR system can be operated continuously on external power by use of 

the recharger/power supply provided.

Connections

Connect the input sensor via the 1/8” [3.5 mm] phone plug to the mating 

connector on the 

SPSR-IM

. This sensor may remain connected even 

when recharging the internal batteries of the 

SPSR-IM

.

NOTE: 

 

Do not plug an input sensor into the SPSR with the Power 

switch in the “ON” position.  Before plugging the sensor in, switch the 

power to “OFF” and unplug any external power supply.
Connect the output signal cable to the BNC connector on the opposite 

end of the 

SPSR-IM

 and to the external equipment to be triggered.  

If operating from the recharger/power supply, connect the recharger to 

the connector marked “External DC” on the 

SPSR-IM 

and connect the 

wall unit to the appropriate power source.  

Controls

The “Power” switch on the 

SPSR-IM

 controls both the operation and the 

charging of the system. The unit will only charge from external power 

in the power OFF position.  In the power ON position, the unit will 

operate directly from external power any time that it is being supplied.  

Otherwise, it functions on internal battery power.
The “Output Selection” switch determines the polarity of the leading 

edge of the TTL compatible output signal.  In the NON-INVERTING 

position, the output signal on the BNC connector will be a negative going 

5 to 0 Vdc pulse derived directly from the conditioned sensor output.  

When the INVERTING position is switch selected, the BNC output 

signal will be a positive going 0 to 5 Vdc, TTL compatible.

SPSR-115/230

(SPSR-IM, ROS-P and Universal Recharger)

Содержание SPSR-115/230 Series

Страница 1: ...red Sensor TTL Pulse Output MONARCH INSTRUMENT Instruction Manual 15 Columbia Drive Amherst NH 03031 USA Phone 603 883 3390 Fax 603 886 3300 E mail support monarchinstrument com Website www monarchinstrument com SPSR 115 230 ...

Страница 2: ...o be RECYCLED in accordance with local regulations contact your local authorities for more information This product may be returnable to your distributor for recycling contact the distributor for details NOTE This product contains Nickel Metal Hydride NiMH batteries which must be recycled Refer to the Battery Disposal section on page 4 for details Monarch Instrument s Limited Warranty applies See ...

Страница 3: ...tion the SPSR system can be operated continuously on external power by use of the recharger power supply provided Connections Connect the input sensor via the 1 8 3 5 mm phone plug to the mating connector on the SPSR IM This sensor may remain connected even when recharging the internal batteries of the SPSR IM NOTE Do not plug an input sensor into the SPSR with the Power switch in the ON position ...

Страница 4: ... aligned to illuminate the reflective target once per revolution It is recommended that the optical sensor be placed at a slight angle approximately 10 15 degrees from perpendicular so that the sensor will detect only the reflected pulses from the target The sensor should be at least 2 inches and no more than 3 feet from the target The green LED On Target Indicator on the ROS P will blink at the i...

Страница 5: ...cator Status indication see LED Indication section Output Connector BNC Connector female Operating Temp 32 F to 122 F 0 C to 50 C Weight 8 3 oz 235 grams Dimensions 5 0 x 2 5 x 1 127 mm x 64 mm x 25 mm 6 ROS P Remote Optical Sensor Operating Envelope Up to 3 feet 0 9 m and 45 from reflective target Speed Range 1 to 250 000 RPM Illumination Source Visible red LED 5 Vdc 30 mA Operating Temp 14 F to ...

Страница 6: ...5 m cable and mounting bracket IRS P Infrared Sensor with 8 foot 2 5 m cable for use without reflective target at 0 5 inch 12 7 mm gap 5 to 500 000 RPM MT 190P Magnetic Trigger Sensor Amplifier with 8 foot 2 5 m cable 0 250 6 4 mm operating gap from target 2 L x 5 8 50 8 x 15 9 mm EC 25P 25 foot 7 6 m Extension Cable for remote sensors with male 1 8 3 5 mm phone plug to female 1 8 3 5 mm connector...

Страница 7: ...ights reserved 1071 4847 118 0619 Check out some of our other product lines Handheld Panel Portable Machine Vision Tachometers Tachometers Stroboscopes Stroboscopes Speed Sensors Temperature Vibration Meters Humidity Sensors Paperless Recorders Track It Data Loggers ...

Отзывы: