background image

 

9. AC 

POWER 

OPTION

The Nova-Pro can be ordered speci

fi

cally with the AC Power Op on for 

con nuous opera on from AC power.  The AC Power Op on can also be 
ordered as a separate op on for the Nova-Pro.  Simply insert the AC  
Power Op on into the Nova-Pro (matching the keyed slot) un l it clicks 
into place.  Then plug the wall power supply into an outlet (115Vac to 
230Vac) using the appropriate interchangeable plug. 

10. WALL POWER SUPPLIES

The wall power supplies provided with the Nova-Pro have  
interchangeable plugs allowing them to be used with AC outlets 

in di

erent countries. 

To change the plugs, depress the bu on (1) and slide the plug up (2).  
Select the correct plug and slide it back into the power supply un l the 
plug seats 

fi

rmly.  Make sure the plug cannot slide out. 

CAUTION:  RISK OF ELECTRIC SHOCK 

x

Do not insert the plugs into an AC 
outlet without the power supply 
a ached. 

x

Avoid touching the plugs when 
inser ng or removing the power 
supply from the AC outlet. 

x

Indoor Use Only. 

31 

 

32 

11. SPECIFICATIONS

Product speci

fi

ca ons are subject to change without no ce. 

Speci

fi

ca

Ɵ

ons  

Nova-Pro UV 385 nm 

Flash Range (FPM/RPM): 

30 to 999,999 

Display:

 

6 digit numeric and 5 digit alphanumeric LCD with touch keypad. High  

contrast blue background/white characters with backlight  

Accuracy/Resolu on:

0.001% of se ng or ±1 lsd/6 digits to 0.001 

Light Source: 

UV 365  nm or UV 385 nm 12 LED Array   

Light output: 

1700

μ

w/cm

@ 12", 1% duty cycle 

Flash Dura on:

Adjustable to 10 degrees/2.000 msecs max 

External Triggers in/out: 

TTL (12Vdc Max) Input. Provides 3.3 Vdc TTL output 

Tachometer Mode: 

0-999,999 RPM with integral laser or external input

Programmable Memory: 

Yes (10 set points) 

Internal Phase Shi :

Yes 

Phase Delay - degrees: 

-360.0 to 345.0 degrees 

Time Delay - milliseconds: 

-50.000 to 50.000 msec 

Virtual RPM 
(Slow Mo on): 

-60.0 to 60.0 VRPM

Opera ng Time: 

Standard ba ery pack: 9.5 hours typical (6000 FPM, 2° duty cycle) 

Hi-capacity ba ery pack (op onal): 19 hours typical (6000 FPM, 2° duty cycle)  

Power Supply (Ba ery):  

Removable/rechargeable Standard Li-Ion ba ery packs (Qty. 2)  

with 115/230 50/60Hz recharging sta on 

Power Supply (A/C):  

115/230 Vac 50/60Hz AC adapter with 6 foot (2M) cable  

and interchangeable outlet adapters (Op onal) 

Weight:

1.4 Lbs. (635 grams) 

Size (H x W x D): 

9.5 x 3.75 x 5.5 in. (241 x 95 x 140mm) 

Housing material/ra ng:  

ABS/IP54 

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание Nova-Pro Ultra Violet UV365

Страница 1: ...Nova Pro Ultra Violet UV365 UV385 Stroboscope Lamp Tachometer Instruction Manual www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 2: ...ed to a reclama on facility for recovery of the metal and plas c components as the proper method of waste management Contact distributor for product return procedures TABLE OF CONTENTS 1 INTRODUCTION...

Страница 3: ...u 21 5 6 1 NONE 22 5 6 2 PHASE 22 5 6 3 TIME 22 5 7 DELAY Menu 22 5 7 1 NONE 23 5 7 2 PHASE 23 5 7 3 TIME 23 5 7 4 VRPM 23 6 STROBE BRIGHTNESS 24 6 1 Calcula ng Blur 24 6 2 Brightness in Degrees of Ro...

Страница 4: ...Table 1 Nova Pro Features 1 2 Bezel and Lens Bezel is removable to add or remove the Laser Module UV Emi ed from here 3 Laser Module Internal laser used to synch the flash to an external marker on th...

Страница 5: ...h Keypad Numeric Used to directly enter precise flash rates 8 TACH icon Ac ve when Tachometer Mode is selected 9 x2 2 and arrows Used to double or halve the flash rate 10 POWER bu on Turns the unit on...

Страница 6: ...Con nuous Opera on The unit can be locked in con nuous opera on by pressing the POWER bu on while squeezing the trigger Keep holding the POWER bu on as you release the trigger and the Lock icon will s...

Страница 7: ...when the digit is changed if incremen ng the units digit 99 will roll over to 100 If the user does not increment or decrement a digit within 5 seconds the edit mode will be cancelled 7 Use joys ck or...

Страница 8: ...00 FMP EVERY OTHER ROTATION 2 One target 3 000 FMP ONCE EVERY ROTATION 0 Two targets 6 000 FMP TWICE PER ROTATION X2 Four targets 12 000 FMP FOUR TIMES PER ROTATION X2 X2 flash each me a signal is rec...

Страница 9: ...THROUGH OPTICAL INSTRUMENTS 4 4 TACH Tachometer Mode The TACH Tachometer Mode requires the Laser Module to be installed OR an external input sensor be plugged in This mode uses the Laser or External...

Страница 10: ...CPT to SET none 1 2 3 RPS FPM FPS Nova Pro 500 and UVxxx Only When using an ex ternal input DOWN but ton MENU but ton POWER but ton NAVIGATIONkeypad DOWN but ton onkeypad KEY 14 SEtUP MODE STROBE MODE...

Страница 11: ...e This will change the mode and exit the menu Press the POWER bu on to escape without changing the mode 5 3 Brightness BRITE Menu Refer to Sec on 8 for details on Brightness and Flash Dura on before u...

Страница 12: ...hout changing the polarity press the Power bu on 19 5 4 5 BKLIT Backlight Menu This menu op on turns the backlight of the display ON or OFF Press the MENU bu on to enter the Backlight menu Use the arr...

Страница 13: ...value of 600 will be displayed as 600 600 0 600 00 600 000 depending on the se ng 17 Press the MENU bu on to enter the DECPT menu The current value is shown on the top line with DECPT on the lower lin...

Страница 14: ...d Jog method The op ons are NONE PHASE and TIME Press the MENU bu on to select a Jog method This will enter the sub menu for PHASE or TIME 21 5 6 1 NONE To cancel the JOG mode press the MENU bu on whe...

Страница 15: ...shing the user can view the e ect of changing the RPM To exit the DELAY Menu press the Power bu on Press the Power bu on to escape back out of the setup menu 6 STROBE BRIGHTNESS The strobe s brightnes...

Страница 16: ...z 25 6 3 Brightness in Pulse Dura on Brightness can also be set to a fixed duration pulse in microseconds The flash rate remains constant irrespective of the flash rate thus as the flash rate increase...

Страница 17: ...respect to the trigger point 27 STOP MOTION 30 60 90 P PHASE TRIGGER POINT 30 60 90 Figure 9 Triggered Phase The Phase Delay tracks the speed of the target the strobe is con nuously compu ng the dela...

Страница 18: ...ppropriate shipping methods 29 The Nova Pro Ba ery Pack is specifically keyed to fit in the Nova Pro and Charger Base one way only Insert the Ba ery Pack into the Nova Pro un l the clips lock into pla...

Страница 19: ...385 nm Flash Range FPM RPM 30 to 999 999 Display 6 digit numeric and 5 digit alphanumeric LCD with touch keypad High contrast blue background white characters with backlight Accuracy Resolu on 0 001...

Страница 20: ...gs Charger Power Supply Replacement power supply for use with Charging Sta on 115 230 Vac with USA UK AUS Euro adapter plugs Standard Ba ery Pack Replacement Standard Li Ion Ba ery Pack Long Life Ba e...

Страница 21: ...other product lines Speed Sensors Temperature Humidity Sensors Vibra on Meters Paperless Recorders Track It Data Loggers Printed in the U S A Copyright 2017 Monarch Instrument all rights reserved 1071...

Отзывы: