background image

 9

8

ESCAPE

button or

LED ON/OFF

Active

SETTING

MENU or

SELECT 

button

Use Rotary Knob or Arrow Buttons to adjust

ESCAPE

button or

LED ON/OFF

Active

SETTING

MENU or

SELECT 

button

Use Rotary Knob or Arrow Buttons to adjust

5.2  WIDTH / CLARITY - 

WIDTH

  

Refer to section 6.0 for further explanation on adjusting the clarity by changing the 

fl

 ash pulse width.

The Width menu option sets the 

fl

 ash duration which a

 ects the perceived brightness 

and consequently the blur or clarity.  This is not to be confused with BRIGHTNESS 

above.  Flash pulse width can be adjusted in Degrees of Rotation, (proportional 

fl

 ash 

duration-changes with 

fl

 ash rate), Percent of Duty Cycle (coming soon), or Time in mil-

liseconds (msec-

fi

 xed 

fl

 ash duration).  Degrees of Rotation and Percent of Duty Cycle 

are mutually exclusive and must be speci

fi

 ed in the MISC, DUTY menu option prior to 

setting the Width.

 

5.2.1  Degree of Rotation Adjustment - 

DEGS

  

If DEGS is set as the Duty Cycle in the MISC menu, DEGS will be displayed when the 

WIDTH menu option is selected.  Adjust the value using the arrow buttons or knob 

and then press the MENU button to accept, which will move to the TIME setting. 

Degrees can be set from 0.1° to 4.0° (3.0° for illumiNova 50). Note: Setting the width 

in degrees keeps the width constant with 

fl

 ash rate as the stroboscope computes the 

degree angle in real time.

 

5.2.2  Percent of Duty Cycle Adjustment - 

PCNT

 (Coming Soon)

  

If PERCNT is set as the Duty Cycle in the MISC menu, PCNT will be displayed 

when the WIDTH menu option is selected.  Adjust the percentage using the arrow 

buttons or knob and then press the MENU button to accept, which will move to 

the TIME setting. Percent of Duty Cycle can be set up to 0.6%. Note: Setting the 

width in Percent of Duty Cycle keeps the percentage constant with 

fl

 ash rate as the 

stroboscope computes the percentage in real time. 

 

5.2.3  Time Pulse Duration Adjustment - 

TIME

  

Regardless of the Duty Cycle setting the the MISC menu, the next width/clarity op-

tion shown when the MENU button is pressed after setting Degrees or Percent is 

Time in microseconds.  Adjust the time value using the arrow buttons or knob and 

then press the MENU button to accept.  Time can be set from 1 to 150 microsec-

onds.  Note: Setting the width by time keeps the 

fl

 ash duration constant, thus the 

clarity will decrease with increasing 

fl

 ash rate. 

5.3  Mode of Operation - 

MODE

  

The MODE options are: Internal, External and ON. See Modes of Operation in section 

3.2 for further details.
To change the Mode, press the MENU button when MODE is displayed and then use 

the UP 

 or DOWN 

buttons or turn the knob to display the desired value (

INT

EXT

ON

). Then press the MENU button to select that option and press the ESCAPE button 

to exit.

5.4  JOG / DELAY

This is MODE dependent. In the Internal Mode this menu option is called JOG; in the 

External Mode this menu option is called DELAY. Refer to section 7.0 on Strobe Delay 

for more details.  
Press the MENU button to select this option, then press the UP 

 or DOWN 

 

buttons or use the rotary knob to select one of the options below:

4.1.4  Doubling or halving the 

fl

 ash rate

To double or halve the 

fl

 ash rate (to check for harmonics) press the MENU button 

twice and the display will show the times 2 and divide by 2 icons at the bottom of 

the display. At this point pressing the LEFT 

 button will double or the RIGHT 

 

button will halve the 

fl

 ash rate. (User can also touch the icons on the display). To 

exit this mode press the ESCAPE button.

4.2 External 

Mode

The strobe must be set in the External Mode from the MODE menu. When the strobe 

is in the External Input Mode, EXT will be displayed.
In the External mode the strobe is triggered by an external source connected to the 

Input connector. See section 3.3.1 Input.
In the External Input Mode the user can’t make any 

fl

ash rate adjustments, 

however there are several functions that rely on the external input to provide a 

reference point for other internal functions. The 

fl

ash rate is a function of the 

external input signal. This mode is used to synchronize the 

fl

ash to an external event 

(for example, from an optical sensor) to stop or freeze motion using an external 

trigger. The 

fl

 ash will be triggered on the rising or falling edge (menu selectable) of 

the external input pulse. 

Note: 

The input pulse can be prescaled using the PRESC menu option in the MISC menu.

4.3 ON 

MODE

The ON mode is selected in the MODE menu option. In this mode the strobe is used 

as a work lamp and appears to be on continuously.

5.0 MENU SETTINGS

The menu settings are used to set several defaults in the Strobe or change the operating 

mode. To get to the settings press the MENU button 3 times (bypass the X2 ÷2 and the 

numeric keypad until the display shows (

SEtUP 

). See page 19 for a full overview of the 

menu options and navigation.
Navigate through the menu using the up and down arrow buttons or rotary knob.  Once 

the desired menu option is displayed, press the MENU button to select that menu option. 

Within the menu options, the currently selected option is indicated by the Active SETTING 

icon (shown in footer). Use the ESCAPE button to escape or back out of the menus.

SETUP

  Using the DOWN arrow 

 

the menu items appear as shown below. If the UP 

arrow 

 is used the menu items will appear in the reverse order. To select the menu 

item press the MENU button.

5.1 BRIGHTNESS 

BRITE

  

There are three levels of brightness: High, Medium and Low. This increases or de-

creases the LED intensity and DOES NOT AFFECT THE PULSE WIDTH. Use the bright-

ness to adjust the intensity to an optimum level for the environment or to minimize 

glare from the target. 
To change the brightness press the MENU button when 

BRITE

 is displayed and then 

use the UP 

 or DOWN 

 buttons or turn the knob to choose the desired option (

HI

MED

LOW

). Then press the MENU button to select that option and press the ESCAPE 

button to exit.

Содержание IllumiNova 100

Страница 1: ...15 Columbia Drive Amherst New Hampshire USA 03031 2334 TEL 603 883 3390 FAX 603 886 3300 www monarchinstrument com the professional s choice IllumiNova USER MANUAL...

Страница 2: ...or death could occur as a result of improper use Please refer to your facility s safety program for proper precautions In order to comply with EU Directive 2012 19 EU on Waste Electrical and Electroni...

Страница 3: ...Laser Inductive Proximity Hall and others Monarch Instrument manufactures a full range of remote sensors for use with all of our strobes and we welcome you to consider purchasing any of these for sim...

Страница 4: ...Common GND Common gray 3 3 2 Output The OUTPUT connector Aviation Plug M12 x 4 has 4 pins 3 of which are used for output signals The strobe has two outputs The first mimics the input pulse and can be...

Страница 5: ...Mode this menu option is called DELAY Refer to section 7 0 on Strobe Delay for more details Press the MENU button to select this option then press the UP or DOWN buttons or use the rotary knob to sel...

Страница 6: ...re mutually exclusive When DUTY is displayed press the MENU button to select and the current selec tion will be displayed as indicated by the Active SETTING icon Use the UP and DOWN arrow buttons or k...

Страница 7: ...limit the value and the DEG icon will blink on the display 6 3 Percent of Duty Cycle Coming Soon The duty cycle between flashes is 100 The user can adjust the duty cycle which is the ratio of on time...

Страница 8: ...he flash width remains constant The degree of rotation visible changes to keep the pulse width of the flash constant The range of width is 1 to 150 microsec onds In the event that the setting exceeds...

Страница 9: ...sors 3 5 Vdc pulse provides 5Vdc sensor power Isolated input 5 12Vdc 50mA max LED Array Size Number of LED s Lux output Available Lens Types Spot Provides narrowest brightest illumination area Wide Pr...

Страница 10: ...ings MISC BRITE input number input number to SET DEG PCNT displayed ON Lamp for ON Off reset Mode to Int or Ext to disable lamp mode Recall setting RM 1 10 to set flash rate Load current flash setting...

Страница 11: ...s Panel Tachometers Portable Stroboscopes Machine Vision Stroboscopes Speed Sensors Temperature Humidity Sensors s D Paperless Recorders Track It Data Loggers Printed in the U S A Copyright Monarch In...

Отзывы: