IllumiNova™  USER MANUAL

 

Содержание IllumiNova 100

Страница 1: ...15 Columbia Drive Amherst New Hampshire USA 03031 2334 TEL 603 883 3390 FAX 603 886 3300 www monarchinstrument com the professional s choice IllumiNova USER MANUAL...

Страница 2: ...or death could occur as a result of improper use Please refer to your facility s safety program for proper precautions In order to comply with EU Directive 2012 19 EU on Waste Electrical and Electroni...

Страница 3: ...Laser Inductive Proximity Hall and others Monarch Instrument manufactures a full range of remote sensors for use with all of our strobes and we welcome you to consider purchasing any of these for sim...

Страница 4: ...Common GND Common gray 3 3 2 Output The OUTPUT connector Aviation Plug M12 x 4 has 4 pins 3 of which are used for output signals The strobe has two outputs The first mimics the input pulse and can be...

Страница 5: ...Mode this menu option is called DELAY Refer to section 7 0 on Strobe Delay for more details Press the MENU button to select this option then press the UP or DOWN buttons or use the rotary knob to sel...

Страница 6: ...re mutually exclusive When DUTY is displayed press the MENU button to select and the current selec tion will be displayed as indicated by the Active SETTING icon Use the UP and DOWN arrow buttons or k...

Страница 7: ...limit the value and the DEG icon will blink on the display 6 3 Percent of Duty Cycle Coming Soon The duty cycle between flashes is 100 The user can adjust the duty cycle which is the ratio of on time...

Страница 8: ...he flash width remains constant The degree of rotation visible changes to keep the pulse width of the flash constant The range of width is 1 to 150 microsec onds In the event that the setting exceeds...

Страница 9: ...sors 3 5 Vdc pulse provides 5Vdc sensor power Isolated input 5 12Vdc 50mA max LED Array Size Number of LED s Lux output Available Lens Types Spot Provides narrowest brightest illumination area Wide Pr...

Страница 10: ...ings MISC BRITE input number input number to SET DEG PCNT displayed ON Lamp for ON Off reset Mode to Int or Ext to disable lamp mode Recall setting RM 1 10 to set flash rate Load current flash setting...

Страница 11: ...s Panel Tachometers Portable Stroboscopes Machine Vision Stroboscopes Speed Sensors Temperature Humidity Sensors s D Paperless Recorders Track It Data Loggers Printed in the U S A Copyright Monarch In...