![Monacor 29.1700 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/monacor/29-1700/29-1700_instruction-manual_1825101011.webp)
7
Specifications
*at 23°C, ±5 °C
According to the manufacturer.
Subject to change.
11
GB
DMT-2505
DMT-2560
Direct voltage
Accuracy*
≤
200 V
1000 V
Input resistance
200 mV, 2 V, 20 V, 200 V, 1000 V
±(0.5 % + 1 digit)
±(0.8 % + 2 digits)
10 M
Ω
200 mV, 2 V, 20 V, 200 V, 1000 V
±(0.5 % + 1 digit)
±(0.8 % + 2 digits)
10 M
Ω
Alternating voltage
Accuracy*
200 mV
2–200 V
750 V resp. 700 V
Frequency range
≤
200 V
750 V resp. 700 V
Input resistance
2 V, 20 V, 200 V, 750 V
—
±(0.8 % + 3 digits)
±(1.2 % + 3 digits)
40–400 Hz
40–400 Hz
10 M
Ω
200 mV, 2 V, 20 V, 200 V, 700 V
±(1.2 % + 3 digits)
±(0.8 % + 3 digits)
±(1.2 % + 3 digits)
40–400 Hz
40–200 Hz
10 M
Ω
Direct current
Accuracy*
≤
20 mA
200 mA
2 A
20 A
200 µ A, 2 mA, 20 mA, 200 mA, 20 A
±(0.8 % + 1 digit)
±(1.2 % + 1 digit)
—
±(2.0 % + 5 digits)
200 µ A, 2 mA, 20 mA, 200 mA, 2 A, 20 A
±(0.8 % + 1 digit)
±(1.2 % + 1 digit)
±(1.2 % + 1 digit)
±(2.0 % + 5 digits)
Resistance
Accuracy*
200
Ω
2 k
Ω
–2 M
Ω
20 M
Ω
200
Ω
, 2 k
Ω
, 20 k
Ω
, 200 k
Ω
, 2 M
Ω
, 20 M
Ω
±(0.8 % + 3 digits)
±(0.8 % + 1 digit)
±(1.0 % + 2 digits)
200
Ω
, 2 k
Ω
, 20 k
Ω
, 200 k
Ω
, 2 M
Ω
, 20 M
Ω
±(0.8 % + 3 digits)
±(0.8 % + 1 digit)
±(1.0 % + 2 digits)
Continuity test
buzzer < 50
Ω
buzzer < 30
Ω
Transistor test at
Display
U
CE
= 3 V, I
B
= 10 µ A
current amplification 0–1000
U
CE
= 2.8 V, I
B
= 10 µ A
current amplification 0–1000
Display
Measuring rate
Power supply
Operating range
Dimensions
Weight
21-mm-LCD, 3
1
/
2
digits
2–3 measurements/s
1 x 9 V battery
0–40 °C, < 75 % humidity
86 x 39 x 162 mm
260 g
21-mm-LCD, 3
1
/
2
digits
2–3 measurements/s
1 x 9 V battery
0–40 °C, < 75 % humidity
88 x 43 x 175 mm
360 g
Alternating current
Accuracy*
200 µ A
2 mA, 20 mA
200 mA
2 A
20 A
Frequency range
2 mA, 20 mA, 200 mA, 20 A
—
±(1.2 % + 3 digits)
±(1.8 % + 3 digits)
—
±(3.0 % + 7 digits)
40–400 Hz
200 µ A, 2 mA, 20 mA, 200 mA, 2 A, 20 A
±(1.8 % + 3 digits)
±(1.2 % + 3 digits)
±(2.0 % + 3 digits)
±(2.0 % + 3 digits)
±(3.0 % + 7 digits)
40–400 Hz
Diode test measuring current
Display
0.8 mA
forward voltage
1 mA
forward voltage