KNO
W
-HOW
E 37
ECM-302B/WS
PA-100ANC
VCA-202RN
VCA-202
Base_DE_001-176.qxd 28.01.2014 14:44 Uhr Seite 37
KNOW-HOW: Remote Volume Control
All rights reserved by MONACOR® INTERNATIONAL GmbH & Co. KG.
A reproduction of this catalogue – or any parts thereof – for any commercial use is prohibited.
PA Technology 2014
The Role of Insert Jacks
Time and again it is necessary to insert additional units like equalizers into a signal way. This
is not a problem with systems set up separately with individual mixers and power amplifiers.
In this case, the signal cables are simply connected to the units. This is different with compact
full amplifiers, as they are customary for PA applications. In this case, the separation is done
by special jacks. With these combined jacks, it is possible to separate the preamplifier with the
inputs (PRE OUT) from the mere power amplifier (AMP IN). The illustration shows the outputs
by example of the
PA-1120
amplifier. Due to the ability to separate, it is now possible to insert
additional units into the signal way.
Two examples of such additional units and their features are shown below.
Automatic Volume Control with PA-100ANC
By using this ambient noise controller, it is possible to achieve a signal
volume depending on the ambient noise. To put it more simple, the
louder the surrounding, the more signal is fed to the speakers.
In practical application it is possible, e.g. to match the volume of the
background music in a restaurant automatically to the noise level of
the rooms. This adjustment is usually slightly delayed and attenuated,
so that short noise peaks will not have any effect on the volume con-
trol.
A microphone is additionally required for the
PA-100ANC
.
Remote Volume Control with VCA-202
The remote volume control is a further requirement which often has to
be met. This is always the case, if the system is not set up at a location
where staff may be nearby. For this purpose, previous solutions includ-
ed the adjustment of the speaker outputs. With the
VCA-202
and
VCA-202RN
, the amplifier output power can now easily be adjusted
remotely. The
VCA-202
is also inserted between preamplifier and
power amplifier. This could be a compact PA amplifier, a mixer with
separate power amplifier or also a CD player and a power amplifier.
A basic cable with a minimum of 3 wires connects the control unit and
the
VCA-202
. Because this cable does not carry an AF signal, shield-
ing is not compulsory. If both inputs of the
VCA-202
are used, the vol-
ume adjustments can either be done together via one control or sepa-
rately via two controls.
GB_001-117.qxd
29.01.2014 12:58 Uhr Seite 37