E 29
PA-1960
PA-1480
Base_DE_001-176.qxd 28.01.2014 14:42 Uhr Seite 29
AM
P
LIFIE
RS
PA Technology 2014
100 V Power Amplifiers
Order No. 17.2550
High-power mono PA amplifier
• 1 x 960 W
RMS
• Additional, adjustable priority input with
switchable priority function
• 100 V slave input for inserting the amplifier
into a 100 V speaker line
• Switchable 400 Hz high-pass filter
6 dB/oct.
• 2 insertion facilities at the rear panel for
optional modules with the following
features:
- PA-6FD: fault detection module
- PA-6FM: fault monitoring module
• Connection for external on/off switch
(remote start)
• Temperature-controlled fan, continuously
adjustable
• LED display for fault, protect, clip, signal,
priority
• Mains operation or 24 V emergency
power operation
Model
PA-1960
Output power
1 x 960 W
RMS
Input sensitivity
0.775 V/60 k
Ω
, bal.
Output impedance
75 V/5.6
Ω
, 85 V/7.2
Ω
, 100 V/10
Ω
Frequency range
35-20,000 Hz
S/N ratio
> 100 dB, A-weighted
THD
< 0.4 %
High-pass filter
400 Hz, 6 dB/oct.
Admiss. ambient temp. 0-40 °C
Power supply
230 V~/50 Hz/2,600 VA,
24 V
‡
/80 A
Dimensions
483x133x374 mm, 3 RS
Weight
25 kg
Connections
Signal input
screw terminals
Speaker output
screw terminals
Other features
Order No. 17.1110
Mono PA power amplifier
• 1 x 480 W
RMS
• Switchable 400 Hz high-pass filter 6 dB/oct.
• Temperature-controlled fan, continuously adjustable
• LED display for clip, protect, overtemperature and output level
• Feed-through output (link)
• Mains operation or 24 V emergency power operation
Model
PA-1480
Output power
1 x 480 W
RMS
Input sensitivity
1.2 V, bal.
Output impedance
62 V/8
Ω
, 70 V/10
Ω
, 100 V/21
Ω
Frequency range
35-20,000 Hz, -3 dB
S/N ratio
> 100 dB, A-weighted
THD
< 1 %
High-pass filter
400 Hz, 6 dB/oct.
Admiss. ambient temp. 0-40 °C
Power supply
230 V~/50 Hz/1,400 VA,
24 V
‡
/40 A
Dimensions
483x88x374 mm, 2 RS
Weight
17.5 kg
Connections
Signal input
XLR / screw terminals
Speaker output
screw terminals
Other features
GB_001-117.qxd
29.01.2014 12:56 Uhr Seite 29