TM42 Termination Press
Order No: TM-690025099
Release Date: 08-08-02
UNCONTROLLED COPY
Page 13 of 49
Revision: H
Revision Date: 01-15-13
Refer to Section 3 for setup, manual cycling, and operation before attempting any crimp terminations under power. If
the press is running, push the emergency stop button located on the front of the press control assembly. The motor
and flywheel will stop. The work light will still operate.
1.
Remove the press guards by removing the (2) M10 BHCS (See Figure 2-4) located on the front bolster plate,
and loosen (1) on each side. Once removed, the guard interlock switch will disconnect power to both the motor
and clutch.
2.
Remove the push rod from the hole on the right side of the bolster plate. If necessary, remove any tooling, and
then remove (2) M10 SHCS attaching the bolster plate to the press frame.
3.
Lift the bolster plate away from the locating dowels by placing a screwdriver in the (2) lifting slots on the underside
of the bolster plate. Remove or install the .50mm (.020”) spacer and verify the presence of the .250mm (.010”)
spacer.
4.
Position the bolster plate on the locating dowels and refasten with the (2) M10 SHCS. Replace the push rod.
Follow the tooling setup procedures in Section 3.
CAUTION
: Always manually cycle the press before restoring power to the machine.