Hand Crimp Tool for Sealed Single Contact Terminals
Doc No: ATS-6382787HM Release Date: 06-05-15
UNCONTROLLED COPY
Page 4 of 9
Revision: A
Revision Date: 06-05-15
TERMINAL
PRE-STRIPPED
WIRE WITH SEAL
Figure 5
WIRE STOP
BLADE
Figure 6
WIRE
INSULATION
PUNCH
CONDUCTOR
ANVIL
LOCATOR
INSULATION ANVIL
WIRES AGAINST
LOCATOR STOP
CONDUCTOR
PUNCH
TERMINAL
SEAL
SWING OPEN
TERMINAL
PUSH HERE TO
OPEN WIRE STOP
LOCATOR
TERMINAL
IN PLACE
Figure 4
LOCATOR LATCH
IN OPEN POSITION
Crimping Terminals
1.
Crimp only the terminal listed in the preceding charts.
2.
Turn the Locator Lock Latch down to unlock. See Figure 3.
3.
Swing the terminal locator away from the crimp tool shown in Figure 4.
4.
Press down on the wire stop on the locator as shown in Figure 4. Insert the terminal into the proper nest
opening. Make sure when choosing the nest opening, it will correspond with the correct profile on the hand
tool.
5.
Return the locator to closed position.
6.
Turn the Locator Lock Latch up to lock. Make sure that the terminal is visually centered over the punch.
7.
Insert the proper wire (with the seal installed) over the terminal.
8.
Gently touch the wire stop with the end of the wire and align the seal with the grips on the terminal. See Figure 5
and 6.
Note
: The tamper proof ratchet action will not release the tool until it has been fully closed.
9.
Crimp the terminal by squeezing the tool handles until the ratchet mechanism cycle has been completed.
Release handles to open the jaws.