Operating Instructions
View a first derivative of a trace
The CT100 can perform a wide range of mathematical transforms of on-screen traces, both in
static and real-time forms. The following example demonstrates the use of the first derivative
plot.
1) Press the
SCAN
button. The
Scan and Trace
menu appears.
2) Press the
SELECT
button until the trace of interest is selected.
3) Select the
Math
option from the
Scan and Trace
menu. The
Math
menu will appear.
4) Select
1
st
Derivative
from the menu.
5) A new trace is created that displays the first derivative of the base trace. See Figure 17.
View a Fast Fourier Transform of a trace
1) Select the live trace with the
SELECT
button.
2) Use the
CURSOR
button and the
HORIZONTAL POSITION
knob to set the boundaries for
the FFT with a cursor at either end.
3) Press the
SCAN
button to open the
Scan
menu.
4) Select the
Math
menu option to open the
Math
menu.
5) Select the
FFT
menu option. The CT100 will now take a high resolution scan of the live
trace between the cursors, then convert the scan into an FFT plot. This may take some
time.
Mohr CT100 / CT100HF Operator's Manual
47
Figure 17: First-derivative plot (top) of an on-screen trace (bottom).
A wide range of mathematical transforms can be easily
implemented.