4.2 Achieving an initial lock
25
4.1.2 DLC configuration
Although the
FSC
can be configured for either internal or external
sweep, it is significantly simpler to use the internal sweep mode and
set the
DLC
as a slave device as follows:
1. Connect
SLOW OUT
to
SWEEP / PZT MOD
on the
DLC
.
2. Enable
DIP9
(
External sweep
) on the
DLC
. Ensure that
DIP13
and
DIP14
are off.
3. Disable
DIP3
(
Bias generation
) of the
FSC
. The
DLC
automati-
cally generates the current feed-forward bias from the sweep
input, so it is not necessary to generate a bias within the
FSC
.
4. Set
SPAN
on the
DLC
to maximum (fully clockwise).
5. Set
FREQUENCY
on the
DLC
to zero using the
LCD
display to
show
Frequency
.
6. Ensure that
SWEEP
on the
FSC
is
INT
.
7. Set
FREQ OFFSET
to mid-range and
SPAN
to full on the
FSC
and observe the laser scan.
8. If the scan is in the wrong direction, invert
DIP4
of the
FSC
or
DIP11
of the
DLC
.
It is important that the
SPAN
knob of the
DLC
is not adjusted
once
set as above, as it will impact the feedback loop and may prevent
the
FSC
from locking. The
FSC
controls should be used to adjust the
sweep.
4.2
Achieving an initial lock
The
SPAN
and
OFFSET
controls of the
FSC
can be used to tune the
laser to sweep across the desired lock point (e.g. cavity resonance)
and to zoom into a smaller scan around the resonance. The following