B. Troubleshooting
The
MOG
labs
DLC
detects a wide range of fault conditions and deac-
tivates related circuitry accordingly. The front-panel
LEDs
provide
indication of the state of these functions.
B.1
STANDBY
/
RUN
indicator
Colour
Status
DARK
Temperature controller off.
Reset via keyswitch,
RUN
→
STANDBY
→
RUN
Possible faults:
•
AC
mains off
•
Interlock(s) disconnected
•
TEC
open or short-circuit
•
TEC
polarity reversed
•
Cable disconnected
•
Temperature sensor disconnected
•
Active temperature sensor connected to
thermistor pins
•
Thermistor connected to active sensor pins
•
Temperature out of range (
< −
5
◦
C or
>
35
◦
C)
•
External sweep selected (
DIP
switch
9
) but
no external sweep supplied
RED
AC
mains power failure (temperature controller off)
ORANGE
Standby (temperature controller on)
GREEN
Fully operational (piezo, current, ramp)