![MOGAS Watson Series Скачать руководство пользователя страница 9](http://html.mh-extra.com/html/mogas/watson-series/watson-series_installation-operation-and-maintenance-manual_1823360009.webp)
© Copyright 03/31/2021 MOGAS Industries, Inc.
www.mogas.com
9
SECURE VALVE IN PLACE
For raised-face flange connections, install flange
gaskets and bolting per customer requirements. When
securing other end types, please contact MOGAS
Service for proper procedures.
Note:
MOGAS valve flanges are supplied in the customary “straddle centerline”
hole orientation, unless otherwise specified.
Straddle centerline hole orientation
PROTECTING THE VALVE
The valve should be lifted with slings around the valve
and not from the stem or actuator.
Flanged raised faces should be protected at all times
prior to installation to prevent possible damage.
Note:
Actuator, gear operators and handle stops are pre-set at the factory
and should not require any further adjustments. Should the actuator or
gear operator require removal for installation, please call the factory or
authorized Service Company first.
POSITION VALVE IN PIPING
Verify that the valve and actuator / handlever
orientation is correct.
Verify that the valve is in the
open
position to prevent
any damage to the ball surface from debris.
Position the valve in line with mating flanges.
Note:
Support or lift as required, using lifting lugs or nylon straps around the
valve body. Do not lift or support by the actuator alone.
3
Installation
2
4
CAUTION!
Temperature and media compatibility should be
verified prior to installation to assure the valve is
able to perform in the desired application.
!