
© Copyright 03/31/2021 MOGAS Industries, Inc.
www.mogas.com
15
INSTALL NEW PACKING RING SET
Apply Krytox™ or equivalent lube inside packing box.
Install the set of packing rings
11
one ring at a time, in
the order as illustrated.
Ensure all rings are snugly fitted all the way down
against the previous ring.
4
RE-INSTALL GLAND FLANGE THRUSTER
AND FLANGE
Slide gland fland thruster
09
over stem
07
and push
snugly against stem packing
11
, followed by gland
flange
10
.
5
09
10
11
Replace Stem Packing