All MOGAS valves operate
counter-clockwise to open, clockwise to close
.
MOGAS valves are supplied in a variety of operator configurations based
upon customer requirements, and may be operated by
• manual actuation (handlever)
• pneumatic actuation
• worm gear actuation (handwheel)
• hydraulic actuation
Each of these operator configurations may be installed and tested prior to
shipping, or shipped separately, depending on customer requirements.
Some valves are supplied with a bare stem or stem adaptor kits to
accommodate a variety of manual or actuated operators.
Please note the configuration of each individual valve and proceed with any
necessary operator adaption procedures prior to installing the valve.
CLOSE
OPEN
Sequential procedure
required to perform operation.
Bold
numbers correspond
with items shown in the
Valve
Item Reference Number
sections.
Warning statement
to prevent unwanted
consequence.
Note(s)
to support
procedure.
All information within this manual is relevant to the safe and proper
care of your MOGAS ball valve. Please understand the following
examples of instructional information:
General information
or
an alternate / variation
procedure.
Read Before Installing Valve
How to Read this Manual
Note:
The normal direction of flow is from the higher pressure end (upstream)
to lower pressure end when the valve is
closed
.
CAUTION!
Ensure key length provides and maintains full
engagement.
THIS WILL AFFECT THE VALVE WARRANTY.
!
PRE-INSTALLATION STORAGE
Valves shall remain stored in their shipping crates
with the lids secured.
INSTALL STEM ADAPTOR
Align stem adaptor
13
so the keyways on stem
adaptor correspond with the keys
6
on stem
5
.