15
KEY (x2)
INDICATOR
SOCKET HEAD
SCREW
37
14
31
05D
05D
52
60
Disassembly
REMOVE OPERATOR ASSEMBLY
Detach the indicator from indicator rod
05D
using
socket head screw.
Remove operator keys by lifting straight up.
Remove mounting adaptor hex nuts
37
.
Lift operator and mounting adaptor assembly
14
straight up and off the valve.
Note:
Use nylon straps around sturdy section of operator
or adaptor.
Remove mounting adaptor studs
31
to provide clear
access to packing area.
Remove hex nut
52
, indicator rod
05D
, and wedge
lock washer