14
Disassembly
NOTICE
Operator packages will vary based on customer
requirements. Operators should be equipped with
position indicators for correct ball bore position.
If position indicators are not visible, the scribe line
on the gland plate
07
can be used to determine the
position of the ball bore. When viewed through the
mounting adptor opening
14
, the stem scribe line
and gland flange scribe line should align.
Note:
To replace valve internal parts, the valve may be repaired
inline
or
removed
from the line.
MARK COMPONENTS
Prior to disassembly, mark any matching components
with a marker, tape, etc. for ease of re-assembly.
ALIGN BALL BORE
Before removing bonnet
03C
, ensure the ball bore is
in alignment to any of three ports.
CAUTION!
If you disassemble, rework and re-assemble this
ball valve,
YOU WILL VOID YOUR WARRANTY
.
1
2